Overheat trip
Tanabe TASK, sprężarka śrubowa olejowa w obudowie
Możliwa przyczyna
Dirty cooler, low oil, fan stopped, blocked intake, thermo valve fault
Co robić
Instrukcja producenta, s. 37Clean, top up, repair fan, clear intake, replace element
Inne usterki Tanabe TASK
Does not start or stops at onceControl panel fault, low voltage, thermal relay trippedAir receiver safety valve blowsUnloader pressure switch, unloader valve or solenoid faultSeparator safety valve blows (high oil pressure)Clogged separator cartridge, minimum pressure valve faultPressure does not rise (stays unloaded)Pressure switch, solenoid or unloader seal ring faultOil flows back to suction filter at stopUnloader solenoid fault or stop delay relay wrongHigh oil content in airClogged separator cartridge, blocked return line, overfillingHigh vibration or noiseWorn mounting rubbers, loose bolts, bearing damage
Na podstawie instrukcji producenta „EM-20-3 INSTRUCTION MANUAL FOR AIR COMPRESSOR”. Przed pracą sprawdź oryginał na statku.