Instruction book for Nakakita's hydraulic remote valve control: butterfly valves on the main engine lube oil and ballast lines carry hydraulic cylinder actuators operated from a control unit in the engine room. A hand pump supplies the pressure; a manually operated 4-way valve per valve directs the oil to open or shut, and in-line flow meters show the open/shut position. The book describes the system, each component (4-way valve, relief combination pilot check valve, self-seal couplings with air purge), the butterfly valves and actuators, troubleshooting, safety and gasket handling.

Kliknij część na modelu, aby zobaczyć jej numer i przeznaczenie.Otwórz trenażer 3D

Procedury obsługi

Operating a remote valve

  1. At the control unit set the 4-way valve of the required valve to OPEN or SHUT. s. 4
  2. Work the hand pump lever back and forth until the in-line flow meter shows the valve has moved fully. s. 4
  3. Return the 4-way valve to neutral. s. 4

Before maintenance on a valve actuator

  1. Make sure the pipe is depressurised and the valve is below 40 °C. s. 49
  2. Isolate power to solenoids and limit switches and shut off the hydraulic/air supply. s. 49
  3. Before opening a spring actuator, slacken the adjusting screw so the spring reaches free length. s. 49

Interwały obsługi technicznej

ElementKiedyCzynnośćInstrukcja
Line pressure, gland and gasket leaksdailyCheck gauge, tighten gland or flange if leakings. 67
Connection boltsevery 3 monthsCheck and tightens. 67
Gaskets, packing and seat1–2 years or at dry dockDismantle, inspect, renews. 67

Usterki i co robić

Dane techniczne

Normal hydraulic pressure5.5 MPa (max 7 MPa, test 10.5 MPa)s. 2
Hydraulic oilISO VG 32 hydraulic oil (e.g. Shell Tellus 32, Mobil DTE 13M)s. 3
Valve steminstall horizontal where possible — vertical stems wear the lower bearings. 28
Hot valvedo not touch above 40 °C without glovess. 49

Źródło: instrukcja producenta „EM-43-2 REMOTE CONTROL EQUIPMENT FOR M-E L.O AND BALLAST PIPE LINE”, 97 stron. Numery stron według oryginału. Przed pracą sprawdź instrukcję na statku.

Strona przetłumaczona automatycznie. Numery części, kody i strony są jak w oryginale.