SeaVint

Nakakita NS286

Comutator de nivel magnetic cu flotor

Nakakita magnetic float level switches for tank and bilge-well level alarms (lube oil sump and gravity tanks, bilge wells, etc.). A float on a stem moves an iron core inside a sealed tube; a magnet outside follows it and actuates a micro switch (SPDT). The manual has one specification sheet per tag (service, fluid, specific gravity, set levels, action high/low), drawings, and instructions to adjust the on-off differential, the magnet stroke and micro-switch operating point, the operating level, installation, wiring, specific-gravity compensation and maintenance. Bilge-well switches work through intrinsically safe switch-operated relays.

Apasă pe o piesă din model pentru a vedea codul și rolul ei.Deschide simulatorul 3D

Proceduri de întreținere

Adjusting the micro switch

  1. Turn the switch adjust screw so that the magnet holder rests 3.8 mm from its attraction position (free position). p. 76
  2. Set the switch operating screw so the micro switch changes over 2.3 mm from the free position. p. 76
  3. For two-switch units insert a 1.5 ± 0.1 mm gauge so the magnet cannot touch the pipe, then set No.1 and No.2 switches with a circuit tester so both actuate together. p. 87
  4. Lock the screws with red lock paint. p. 88

Changing the operating level

  1. Turn the knob to move the whole switch unit up or down within the ±10 mm scale. p. 88
  2. For larger changes move the upper or lower limit float on the stem, measuring from the flange face to the level band. p. 88

Yearly check

  1. Switch off the power, measure insulation resistance. p. 94
  2. Test with water and confirm actuation; remember the mark is for the design specific gravity, so with water it actuates lower. p. 94
  3. If the point deviates more than 5 mm, open it, wipe deposits off the tube and iron core and reassemble with match marks. p. 94

Intervale de întreținere

ElementCândAcțiuneManual
Each level switchevery yearIndependent function test; clean tube and iron core if the actuation point has drifted more than 5 mmp. 94

Defecte și ce trebuie făcut

Specificații tehnice

Body / float materialSS400 body, SUS304 float (typical sheet)p. 3
ContactSPDT micro switch, AC 250 V 5 A / DC 250 V 0.3 A resistivep. 3
Insulation testDC 500 V megger, over 100 MΩp. 3
Withstand voltageAC 1500 V for 1 minutep. 3
Set level accuracy±10 mm on sheet; setting precision within ±5 mmp. 89
On-off differentialabout 10–30 mm standard; adjustable ±25 mm by range platesp. 66
Magnet free position3.8 mm from attraction positionp. 76
Micro switch operating point2.3 mm from free position; differential 0.2–0.7 mmp. 76
Operating level change±10 mm by the knob on the switchp. 86

Sursa: manualul producătorului „EM-36 LEVEL SWITCH”, 95 pagini. Numerele paginilor se referă la original. Înainte de lucru, verifică manualul de la bord.

Pagina a fost tradusă automat. Codurile de piese, codurile de eroare și paginile sunt ca în original.