SeaVint

Abnormal noise in the crankcase

Tanabe LSHC-20B/30A/40A, two-stage air-cooled reciprocating air compressor (emergency / service air)

Possible cause

Worn main or rod bearing, loose connecting rod bolt

What to do

Replace or adjust bearings, retighten rod bolts to 480 kgf·cm

Manufacturer's manual, p. 27

See the assembly on the 3D model

Other Tanabe LSHC-20B/30A/40A faults

From the manufacturer's manual “EM-20-4 INSTRUCTION MANUAL FOR TANABE AIR COMPRESSOR TYPE LSHC”. Check against the original on board before work.