Brake becomes warm
MacGregor-Hägglunds HH 160-0520, electro-hydraulic hose handling crane
Possible cause
Release pressure too low, or constant upstream pressure on the brake
What to do
Manufacturer's manual, p. 73Check that the release pressure is high enough
See the assembly on the 3D model
Other MacGregor-Hägglunds HH 160-0520 faults
A crane function fails or works irregularlyElectrical, hydraulic or mechanical fault in the hoisting, luffing or slewing circuitBrake moment drops (slewing gear / winch brake)Disc assembly worn or clogged, or dry runningContinuous loss of gear oil in the slewing gearLeaking seals