SeaVint

Brake becomes warm

MacGregor-Hägglunds HH 160-0520, electro-hydraulic hose handling crane

Possible cause

Release pressure too low, or constant upstream pressure on the brake

What to do

Check that the release pressure is high enough

Manufacturer's manual, p. 73

See the assembly on the 3D model

Other MacGregor-Hägglunds HH 160-0520 faults

From the manufacturer's manual “MacGregor_HH160-0520_hose_crane_manual”. Check against the original on board before work.