Emulsified lubricating oil

Tanabe VLHH-64A / 74A, v-type air-cooled 3-stage reciprocating compressor

Possible cause

Humid room, drain not purged often enough

What to do

Ventilate; set drain timer to 5–10 s every 10–15 min; vent drain line to atmosphere

Manufacturer's manual, p. 33

See the assembly on the 3D model

Other Tanabe VLHH-64A / 74A faults

From the manufacturer's manual “EM-20-5 INSTRUCTION MANUAL FOR TANABE AIR COMPRESSOR TYPE VLHH”. Check against the original on board before work.