Stern tube oil above 60 °C

Kobelco Compact Seal CX-500, oil-lubricated stern tube seals (aft and forward)

Possible cause

Bearing damage, cooler or thermometer fault

What to do

Check for white metal, slow down, repair cooler

Manufacturer's manual, p. 31

See the assembly on the 3D model