Exhaust temperature rises on one cylinder
MAN B&W L23/30H — tehničke informacije, četverotaktni pomoćni dizelski motor (agregat)
Mogući uzrok
Defective fuel valve, leaking exhaust valve, blow-by, damaged fuel cam
Što učiniti
Priručnik proizvođača, str. 37Overhaul fuel valve, change cylinder head, pull piston
Ostali kvarovi MAN B&W L23/30H — tehničke informacije
Exhaust temperature rises on all cylindersCharge air cooler ineffective, fouled air/gas passages, poor fuel, wrong camshaft positionExhaust temperature drops on one cylinderAir in fuel pump, sticking fuel valve spindle, sticking pump plungerEngine rpm dropsLow fuel pressure, water in fuel, governor or valve faults, increased frictionSmoky exhaust in normal runningFouled turbocharger, defective nozzles, low air supplyExhaust valve knockingLoose adjusting screw, damaged push-rod discLube oil pressure failsPump defective, filters or cooler fouledEngine does not turn on startLow air pressure, main valve closed, pinion not engaging, start valve stuck, electrical fault
Prema priručniku proizvođača „MAN L23-30H technical information”. Prije rada provjerite izvornik na brodu.