Water level below the lowest visible part of the gauge
Zhongde LYF2.0/300-0.7, ketel komposit (berbahan bakar dan gas buang)
Kemungkinan penyebab
Feed failure or level control fault
Yang harus dilakukan
Manual produsen, hlm. 92Stop the burner immediately, close the steam valve slowly, cool down and inspect before restart
Gangguan Zhongde LYF2.0/300-0.7 lainnya
Brown water in the gauge glass / primingOil or dirt in the boiler waterSafety valve does not lift at set pressureSticking or wrongly set valveHeating surface red-hot or deformedOverheating, low water or scaleCoke or smoke in the furnaceBurner out of adjustmentWater level gauge leaksLoose nuts or worn cock packing
Dari manual produsen “EM-3 ZHONGDE BOILER”. Periksa dokumen asli di kapal sebelum bekerja.