Discharge pump gives no flow
Hamworthy Super Trident ST6A, biological (aerobic) sewage treatment plant, imo mepc.2(vi)
Iespējamais cēlonis
Closed valves, blocked suction, air leaks or loops in suction pipe
Ko darīt
Ražotāja rokasgrāmata, 70. lpp.Open valves, clean suction, fix joints and pipe loops
Citi Hamworthy Super Trident ST6A bojājumi
Tank overflow / high level alarmDischarge pump failure, pipe blockage or excessive inflow (leaking WC flush valves)Bad smell from the unitAnaerobic tank: compressor, air-lifts or diffusers not working, or too much sludgePoor effluent qualityLack of oxygen, killed bacteria by disinfectant cleaners, sludge not returning, too much flushing waterScum on the settling tankSkimmer or air-lifts not workingFoaming in the aeration tank and ventToo much cleaning agentReduced or irregular pump dischargeChoked impeller, valve or non-return valve partly closedAir gauge 0.2 bar above normal / relief valve blowingClogged diffuser elements or dirty filters
Pēc ražotāja rokasgrāmatas “Sewage treatment plant manual”. Pirms darba pārbaudiet oriģinālu uz kuģa.