Water level gauge leaks
Zhongde LYF2.0/300-0.7, composite boiler (oil-fired and exhaust gas)
Iespējamais cēlonis
Loose nuts or worn cock packing
Ko darīt
Ražotāja rokasgrāmata, 13. lpp.Retighten union nuts and bottom screws; if it still leaks renew the packing sleeve or cock plug
Citi Zhongde LYF2.0/300-0.7 bojājumi
Water level below the lowest visible part of the gaugeFeed failure or level control faultBrown water in the gauge glass / primingOil or dirt in the boiler waterSafety valve does not lift at set pressureSticking or wrongly set valveHeating surface red-hot or deformedOverheating, low water or scaleCoke or smoke in the furnaceBurner out of adjustment
Pēc ražotāja rokasgrāmatas “EM-3 ZHONGDE BOILER”. Pirms darba pārbaudiet oriģinālu uz kuģa.
Lappuse tulkota automātiski. Detaļu numuri, kodi un lappuses ir kā oriģinālā.