Flue gas temperature high alarm
TeamTec Golar OG 200, 船用焚烧炉(油泥、污水污泥和固体垃圾)
可能原因
Above set value (normal 400 °C), faulty controller u1 or thermocouple
处理方法
制造商说明书,第 47 页Check temperature and settings, controller and thermocouple
TeamTec Golar OG 200 的其他故障
Flame failure alarm at startNo ignition spark, diesel solenoids not opening, dirty nozzle, too much primary air, dirty photo resistor, poor oilFlame failure when stage 2 startsToo much primary air, damper opening too earlyLow diesel oil pressure alarmNo oil supply, faulty pressure switch b13, pump problemDraught failure alarmLow furnace negative pressure, damper in manual, controller settings, blown fuse, faulty controller or damper motorCombustion chamber temperature high alarmAbove 1200 °C, faulty controller u2 or thermocoupleSludge dosage valve does not startCirculating pump off, chamber below 600 °C, relay, inverter or motor faultSludge dosage valve stops after a whileChamber temperature falls (wet sludge) or motor overload (OL2 on inverter)No flame from the sludge burnerSteam/air solenoid, low atomising pressure, too much water or air, damaged sludge nozzleLow sludge / steam pressure alarmSludge below 0.5–1 bar or steam/air below 6–9 bar, closed valves, faulty switchesFlue gas fan does not startTripped breaker e11, contactor, motor or switch
依据制造商说明书《EM-10 INCINERATOR》。作业前请核对船上的原件。
本页为自动翻译。零件号、代码和页码与原文一致。