Hoisting motor overheats
Zhenjiang SAPC21, single-arm slewing boat and raft davit
Possible cause
Shorted turns, voltage too high or low, overload, too many starts, brake opens late, wrong speed switching
What to do
Manufacturer's manual, p. 47Check winding, voltage, load, operating method, brake voltage and air gap, switching sequence
See the assembly on the 3D model
Other Zhenjiang SAPC21 faults
Hoisting motor does not start at no loadFeed lines broken, one stator phase broken, abnormal voltage or frequency, motor brake not workingHoisting motor does not start under loadLow voltage, short circuit between turns, overload, broken rotor bars, brake not workingBoat or raft lowers too far after stoppingBrake slippingAccumulator low-pressure alarmOil pressure dropped
From the manufacturer's manual “SAPC21 single arm slewing boat and raft davit”. Check against the original on board before work.