Low outlet air flow
Atlas Copco CD 25+…260+, adsorptive air dryer (cold regeneration)
Possible cause
Too much air diverted to purge
What to do
Manufacturer's manual, p. 81Inspect and, if necessary, replace solenoid valve; verify nozzle is set for operating pressure (standard – 7 bar)
See the assembly on the 3D model
Other Atlas Copco CD 25+…260+ faults
High dew‑point, PDP warning/alarm activeAdsorbent did not complete regenerationHigh dew‑point: silencers cloggedSilencers cloggedHigh dew‑point: filter drain not operatingFilter drain not operatingHigh dew‑point: excessive flow through dryerExcessive flow through dryerHigh dew‑point: low outlet pressureLow outlet pressureHigh dew‑point: high inlet temperatureHigh inlet temperatureFree water in dryerWater separator / filter drain before dryer not operatingExcessive noiseSilencer damaged or poorly secured
From the manufacturer's manual “CD_plus_25-260_Instruction_Book_EN_Antwerp_2920711111”. Check against the original on board before work.