ERR 4 — memory error
JOWA SEAGUARD, 15 ppm bilge alarm (ows monitor)
Possible cause
Memory card loose or faulty (corroded contacts)
What to do
Manufacturer's manual, p. 22Check the card and restart; replace the card; if needed, reset by removing the battery for 24 h and set the time
See the assembly on the 3D model
Other JOWA SEAGUARD faults
ERR 2 — clock failureHardware failureERR 8 — sensor not connectedBroken/loose cable or faulty sensorERR 10 — sensor cleaning requiredNo clean water, dirty sensor, failed auto-flush, air bubbles, faulty sensorERR 20 — sensor temperatureTemperature outside +1…+60 °C or faulty sensorERR 40 — log truncatedLog recording interrupted by power failureERR 80 — unknown errorSoftware failure or no ID in the Information menuPPM: O/R — out of rangeValue outside 0–30 ppm, sample too dirty, faulty sensor
From the manufacturer's manual “Manual JOWA SEAGUARD”. Check against the original on board before work.