ERR 4 — memory error
JOWA SEAGUARD, alarm kaljuže 15 ppm (ows monitor)
Mogući uzrok
Memory card loose or faulty (corroded contacts)
Što učiniti
Priručnik proizvođača, str. 22Check the card and restart; replace the card; if needed, reset by removing the battery for 24 h and set the time
Ostali kvarovi JOWA SEAGUARD
ERR 2 — clock failureHardware failureERR 8 — sensor not connectedBroken/loose cable or faulty sensorERR 10 — sensor cleaning requiredNo clean water, dirty sensor, failed auto-flush, air bubbles, faulty sensorERR 20 — sensor temperatureTemperature outside +1…+60 °C or faulty sensorERR 40 — log truncatedLog recording interrupted by power failureERR 80 — unknown errorSoftware failure or no ID in the Information menuPPM: O/R — out of rangeValue outside 0–30 ppm, sample too dirty, faulty sensor
Prema priručniku proizvođača „Manual JOWA SEAGUARD”. Prije rada provjerite izvornik na brodu.
Stranica je automatski prevedena. Brojevi dijelova, kôdovi i stranice su kao u izvorniku.