ERR 2 — clock failure
JOWA SEAGUARD, alarm kaljuže 15 ppm (ows monitor)
Mogući uzrok
Hardware failure
Što učiniti
Priručnik proizvođača, str. 22Switch off, remove the battery from the control unit for 24 h, switch on, set GMT time and date, refit the battery; otherwise replace the CPU board
Ostali kvarovi JOWA SEAGUARD
ERR 4 — memory errorMemory card loose or faulty (corroded contacts)ERR 8 — sensor not connectedBroken/loose cable or faulty sensorERR 10 — sensor cleaning requiredNo clean water, dirty sensor, failed auto-flush, air bubbles, faulty sensorERR 20 — sensor temperatureTemperature outside +1…+60 °C or faulty sensorERR 40 — log truncatedLog recording interrupted by power failureERR 80 — unknown errorSoftware failure or no ID in the Information menuPPM: O/R — out of rangeValue outside 0–30 ppm, sample too dirty, faulty sensor
Prema priručniku proizvođača „Manual JOWA SEAGUARD”. Prije rada provjerite izvornik na brodu.
Stranica je automatski prevedena. Brojevi dijelova, kôdovi i stranice su kao u izvorniku.