PPM: O/R — out of range
JOWA SEAGUARD, 15 ppm bilge alarm (ows monitor)
Possible cause
Value outside 0–30 ppm, sample too dirty, faulty sensor
What to do
Manufacturer's manual, p. 22Clean the sensor and calibrate on clean water, check the sample, replace the sensor
See the assembly on the 3D model
Other JOWA SEAGUARD faults
ERR 2 — clock failureHardware failureERR 4 — memory errorMemory card loose or faulty (corroded contacts)ERR 8 — sensor not connectedBroken/loose cable or faulty sensorERR 10 — sensor cleaning requiredNo clean water, dirty sensor, failed auto-flush, air bubbles, faulty sensorERR 20 — sensor temperatureTemperature outside +1…+60 °C or faulty sensorERR 40 — log truncatedLog recording interrupted by power failureERR 80 — unknown errorSoftware failure or no ID in the Information menu
From the manufacturer's manual “Manual JOWA SEAGUARD”. Check against the original on board before work.