Low sludge / steam pressure alarm
TeamTec Golar OG 200, insinerator kapal (minyak lumpur, lumpur limbah dan sampah padat)
Kemungkinan penyebab
Sludge below 0.5–1 bar or steam/air below 6–9 bar, closed valves, faulty switches
Yang harus dilakukan
Manual produsen, hlm. 47Adjust supply pressures, open valves, check switches b14 (0.2 bar) and b21 (2 bar)
Gangguan TeamTec Golar OG 200 lainnya
Flame failure alarm at startNo ignition spark, diesel solenoids not opening, dirty nozzle, too much primary air, dirty photo resistor, poor oilFlame failure when stage 2 startsToo much primary air, damper opening too earlyLow diesel oil pressure alarmNo oil supply, faulty pressure switch b13, pump problemDraught failure alarmLow furnace negative pressure, damper in manual, controller settings, blown fuse, faulty controller or damper motorFlue gas temperature high alarmAbove set value (normal 400 °C), faulty controller u1 or thermocoupleCombustion chamber temperature high alarmAbove 1200 °C, faulty controller u2 or thermocoupleSludge dosage valve does not startCirculating pump off, chamber below 600 °C, relay, inverter or motor faultSludge dosage valve stops after a whileChamber temperature falls (wet sludge) or motor overload (OL2 on inverter)No flame from the sludge burnerSteam/air solenoid, low atomising pressure, too much water or air, damaged sludge nozzleFlue gas fan does not startTripped breaker e11, contactor, motor or switch
Dari manual produsen “EM-10 INCINERATOR”. Periksa dokumen asli di kapal sebelum bekerja.