10.2.3 Exhaust gas cleaning system (EGCS)
Rotational 1ChemicalLNGLPGOilAsked to: Chief Engineer, Engineer officersWhere: Chief Engineer's Office, Engine Control Room, Engine RoomOnly if it applies to the ship
Where an exhaust gas cleaning system (scrubber) is fitted, do the engineers know the company procedures for running, calibrating and maintaining it, and are the safety and regulatory requirements being met?
In one lineWe run and calibrate the scrubber per its approved manuals; if it fails we switch to compliant fuel, record it and notify the authorities.
How to answer
- Explain the operating modes fitted (open/closed/hybrid) and when each is used, including ports or areas that prohibit open-loop discharge
- Describe the calibration routine for gas analysers and washwater sensors and where it is recorded
- Explain the failure procedure: if the system cannot keep emissions compliant, change over to compliant fuel, record, and report to the flag and next port state as required under MARPOL Annex VI
- Describe inspection of the overboard valve and washwater pipe, and how leaks would be detected and reported
- Mention safe handling of caustic soda or other chemicals and residue/sludge disposal records
What the inspector looks for
- Approved technical and onboard monitoring manuals on board, plus the EGCS record book
- Continuous emission monitoring (SO2/CO2 ratio) and washwater monitoring (pH, PAH, turbidity) working and calibrated
- Washwater overboard valve and piping condition (corrosion is a known risk)
- Procedure for EGCS failure: changeover to compliant fuel and notification of flag/port state
- Awareness of local bans on open-loop discharge and records of mode changes
- Chemicals (e.g. caustic soda for closed loop) stored and handled safely with PPE
Have ready to show
- EGCS technical manual and onboard monitoring manual
- EGC record book / mode change log
- Calibration certificates and records for analysers and sensors
- Continuous monitoring data display/recorder
- Records of malfunctions and notifications to authorities
- Washwater overboard valve and piping
- Chemical storage and PPE, residue discharge records
Avoid
- Analysers out of calibration or data gaps not explained
- Corroded or leaking washwater piping or overboard valve
- Engineers not knowing what to do when the EGCS fails
- Open-loop operation in an area where it is banned
Practise in the interview trainer All questions