10.6.1 LNG fuel tank water-spray system
Rotational 2ChemicalLPGOilAsked to: Master, Chief Officer, 2nd / 3rd OfficerWhere: Main DeckOnly if it applies to the ship
On a ship that burns LNG as fuel, do the Master and officers know where the fuel tank water-spray system is, what it is for and how to operate it for cooling and fire protection on deck, and is it in good working order and regularly inspected, tested and maintained?
In one lineThe water spray cools and protects the LNG fuel tank; I can start the pumps, set and drain the valves; tests are recorded.
How to answer
- Explain that the spray system cools the tank and protects it and adjacent structure from heat radiation in a fire, as required by the IGF Code for fuel tanks on open deck
- Describe how you start the pumps locally and remotely and open the section valves
- Point out the isolating and stop valves and explain the drain points used to empty the deck lines and prevent freezing or corrosion
- Describe the test routine, how blocked nozzles are found and cleared, and where it is recorded
What the inspector looks for
- Officers know the purpose: cooling the LNG fuel tank and protecting it and nearby structure in a fire
- Water spray pump start positions (local and remote) known
- Isolating valves, stop valves and drain points known and in the correct position
- Nozzles clear and piping free of corrosion; system drained to prevent freezing
- Periodic tests recorded
Have ready to show
- Water spray system piping, nozzles and valves around the LNG fuel tank
- Fire pump/water spray pump start positions
- Fire control plan showing the system
- Test and maintenance records in the PMS
- System operating instructions
Avoid
- Officers unable to start the system or find the valves
- Blocked nozzles or corroded piping
- No records of testing
On SeaVint
Practise in the interview trainer All questions