10.6.4 LNG fuel bunkering control station and manifold
Rotational 2ChemicalLPGOilAsked to: Chief Engineer, Engineer officersWhere: Aft Mooring Deck, Main DeckOnly if it applies to the ship
Are the safety arrangements at the LNG fuel bunkering control station and at the bunkering manifold in good condition?
In one lineThe LNG bunker station has working drip trays, water curtain, gas detection, ESD and fire-fighting equipment, all tested before bunkering and recorded.
How to answer
- Show the manifold safety equipment and explain its purpose: drip tray for cryogenic spills, water curtain to protect steel from embrittlement
- Explain the readiness checks before bunkering: water curtain running, gas detectors tested, ESD tested, fire-fighting equipment in place
- Describe how the control station monitors tank level, pressure and temperature during bunkering
- Mention the remote emergency stops for fuel and lube oil pumps and the quick closing valves, and how they are tested, if asked
What the inspector looks for
- Drip trays of suitable cryogenic-resistant material, clean and drainable
- Water curtain to protect the hull and its test records
- Gas detection, fire detection and fire-fighting (dry powder, water spray) at the station
- ESD push buttons, communication, lighting and signage in order
- Insulating flange and blank flanges, manifold valves and pressure gauges in good condition
Have ready to show
- Bunkering manifold with drip trays and water curtain
- Bunkering control station panels
- Gas and fire detection test records
- Fire extinguishers and dry powder system at the station
- PMS records for bunkering equipment
- Signage and safety zone markings
Avoid
- Corroded or damaged drip trays or water curtain piping
- Gas detectors overdue for test
- Missing signage or blocked access