10.7.2 Fire prevention in machinery spaces - hot surfaces and oil spray
Rotational 1ChemicalLNGLPGOilAsked to: Chief Engineer, Engineer officersWhere: Engine Room
Do the Master and officers know the measures in place to prevent fuel or other flammable liquid spraying onto hot surfaces and causing an engine room fire, and are these protective measures regularly inspected and kept in good condition?
In one lineHot surfaces are insulated, HP fuel pipes are jacketed with leak alarms, flanges have spray protection, and leaks are fixed and cleaned immediately.
How to answer
- Explain the main measures: insulation of surfaces above 220 °C, double-walled high-pressure fuel pipes, spray protection on flanged joints, and prompt cleaning of oil leaks
- Describe how you test the fuel leakage alarm: fill the leak detection tank or lift the float until the alarm sounds, then reset and record
- Explain that removed insulation must be replaced after maintenance and that oil-soaked lagging is renewed
- Mention reference guidance such as IMO MSC.1/Circ.1321 on preventing engine room fires, if relevant
- Describe what you do if you find a leak: report, isolate, clean up and repair
What the inspector looks for
- Hot surfaces (exhaust manifolds, turbochargers, indicator cocks) fully insulated; insulation not oil-soaked or missing
- Jacketed high-pressure fuel pipes with leakage collection and alarm working
- Spray shields or anti-splash tape on flanges near hot surfaces
- Regular thermographic surveys or temperature checks where required
- Leakage alarm tested and recorded
Have ready to show
- Insulated hot surfaces on main engine, generators and boilers
- High-pressure fuel pipe leakage alarm and collection tank
- Anti-splash tape/spray shields on flanges
- Leakage alarm test records
- Thermographic survey report (if done)
- PMS records for insulation inspection
Avoid
- Missing or oil-soaked insulation
- Disabled leak detection alarms
- Spray shields not refitted after maintenance