11.1.14 One hose crane hoisting winch, stowed wire and limit switches
CoreChemicalLNGLPGOilWhere: Main Deck
Does the operator's submitted photograph No. 14 (one hose crane hoist winch, the stowed wire and the limit switches) match what the inspector actually sees on board on the day, and is that area free from anything of concern?
In one lineThe hoist wire is greased and undamaged, spooled correctly, with a certificate; limit switches are tested and work.
How to answer
- Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
- Explain how often the wire is inspected and greased, and when it was last renewed
- Describe how limit switches are tested before use and the record kept
- If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
What the inspector looks for
- Whether the submitted photo is a true, current picture of the area
- Wire condition: no broken strands, kinks, corrosion; lubricated
- Wire spooled neatly on the drum with sufficient turns
- Limit switches (hoist, luff, slew) fitted and tested
- Wire certificate on board and renewal records
Have ready to show
- The submitted photograph and the same viewpoint on board
- Wire rope certificate
- Limit switch test records
- Crane PMS records
Avoid
- A photo that shows a better condition than the area actually has on the day
- Dry, corroded or damaged wire
- Limit switches bypassed or not working
On SeaVint
← 11.1.13 One hose crane with an overall view11.1.15 Starboard manifold looking from aft to forward →
Practise in the interview trainer All questions
An independent guide written by seafarers for seafarers. It is not affiliated with or endorsed by OCIMF and does not reproduce the SIRE 2.0 Question Library: questions are put in our own words. The official library and guidance are published by OCIMF (ocimf.org). Always follow your company's SMS.