SeaVint

Chapter 11. General appearance and condition (photographs)

54 questions with how to answer each.

11.1.1 Bow area from dead ahead Core

Does the operator's submitted photograph No. 1 (the bow seen from dead ahead) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe bow looks as in the photo: markings legible, anchors secured, coating maintained and any damage reported.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Point out recent touch-up or painting and the hull maintenance plan
  • Explain any dents or damage and show the defect report and class/company notification
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Hull maintenance/painting records
  • Defect reports for any hull damage
  • Anchor and windlass maintenance records

11.1.2 Hull forward end starboard side Core

Does the operator's submitted photograph No. 2 (the forward part of the hull, starboard side) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe starboard forward hull matches the photo: markings clear, coating maintained, any damage reported and assessed.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain the hull painting/touch-up programme and recent work done
  • Show any reported contact damage with its defect report and assessment
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Hull maintenance and painting records
  • Defect reports and class records for any hull damage
  • Recent hull survey or dry-dock report

11.1.3 Hull forward end port side Core

Does the operator's submitted photograph No. 3 (the forward part of the hull, port side) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe port forward hull matches the photo: markings clear, coating maintained, any damage reported and assessed.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain the hull painting/touch-up programme and recent work done
  • Show any reported contact damage with its defect report and assessment
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Hull maintenance and painting records
  • Defect reports and class records for any hull damage
  • Recent hull survey or dry-dock report

11.1.4 Hull aft end starboard side Core

Does the operator's submitted photograph No. 4 (the aft part of the hull, starboard side) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe starboard aft hull matches the photo: markings clear, coating maintained, any damage reported and assessed.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain the hull painting/touch-up programme and recent work done
  • Show any reported contact damage with its defect report and assessment
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Hull maintenance and painting records
  • Defect reports and class records for any hull damage
  • Recent hull survey or dry-dock report

11.1.5 Hull aft end port side Core

Does the operator's submitted photograph No. 5 (the aft part of the hull, port side) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe port aft hull matches the photo: markings clear, coating maintained, any damage reported and assessed.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain the hull painting/touch-up programme and recent work done
  • Show any reported contact damage with its defect report and assessment
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Hull maintenance and painting records
  • Defect reports and class records for any hull damage
  • Recent hull survey or dry-dock report

11.1.6 Transom from right astern Core

Does the operator's submitted photograph No. 6 (the transom from right astern) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe transom matches the photo: name legible, coating maintained, fittings and lights intact, any damage reported.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain any maintenance done on the stern area and show the record
  • Point out the stern lights and aft towing fittings and their condition
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Hull painting records
  • Defect reports for stern damage
  • Navigation light test records

11.1.7 Forecastle port side looking towards fairleads Core

Does the operator's submitted photograph No. 7 (the forecastle, port side, looking towards the fairleads) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe port forecastle matches the photo: fairleads and rollers free and smooth, bitts sound, deck coated and tidy.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain the greasing and inspection routine for rollers and fairleads under the PMS
  • Point out any wear or grooving and the planned repair, with the defect report
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • PMS records for mooring fittings
  • Mooring System Management Plan / mooring equipment records
  • Defect reports for forecastle fittings

11.1.8 Forecastle starboard side looking towards fairleads Core

Does the operator's submitted photograph No. 8 (the forecastle, starboard side, looking towards the fairleads) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe starboard forecastle matches the photo: fairleads and rollers free and smooth, bitts sound, deck coated and tidy.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain the greasing and inspection routine for rollers and fairleads under the PMS
  • Point out any wear or grooving and the planned repair, with the defect report
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • PMS records for mooring fittings
  • Mooring System Management Plan / mooring equipment records
  • Defect reports for forecastle fittings

11.1.9 Port or starboard windlass Core

Does the operator's submitted photograph No. 9 (one windlass, port or starboard) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe windlass matches the photo: no leaks, brake and linings in good order, stopper secured and maintenance recorded.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain the windlass maintenance routine: greasing, brake lining inspection, brake test
  • Show the latest brake test or brake holding capacity check and lining condition record
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Windlass PMS records
  • Brake test records
  • Hydraulic oil analysis if applicable
  • Anchoring equipment defect reports

11.1.10 Forward main deck showing condition of deck (and external framing) Core

Does the operator's submitted photograph No. 10 (the forward main deck, showing deck condition and any external framing) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe forward main deck matches the photo: coating maintained, framing sound, walkways and fittings in good order.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain the deck maintenance plan and progress of chipping/painting
  • Point out any repaired areas and show the records
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Deck maintenance/painting plan and records
  • Defect reports for structure
  • Class survey records

11.1.11 Forward main deck showing condition of Piperack Core

Does the operator's submitted photograph No. 11 (the forward main deck pipe rack) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe forward pipe rack matches the photo: pipes and supports coated and sound, no temporary repairs, lines tested and recorded.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain how pipelines are inspected and pressure tested under the PMS
  • Show records for any pipe renewal or repair and confirm no temporary repairs exist
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Pipeline pressure test records
  • PMS records for deck pipelines
  • Defect reports for pipe rack

11.1.12 One mooring winch including the brake setting arrangement Core

Does the operator's submitted photograph No. 12 (a mooring winch and the way its brake is set) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe winch matches the photo: brake linings and setting marks in good order, brake tested on schedule, no leaks.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain how the brake is set and tightened (torque or marks) and the brake holding test interval
  • Show the latest brake test results and brake lining inspection
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Brake test records
  • Mooring System Management Plan and mooring line records
  • Winch PMS records

11.1.13 One hose crane with an overall view Core

Does the operator's submitted photograph No. 13 (an overall view of one hose handling crane) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe hose crane matches the photo: structure sound, SWL marked, certificates valid and no hydraulic leaks.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain the crane inspection and maintenance routine, including annual thorough examination and periodic load tests
  • Show the lifting appliance register and certificates
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Cargo gear register / lifting appliances certificates
  • Crane PMS records
  • Hydraulic oil analysis results

11.1.14 One hose crane hoisting winch, stowed wire and limit switches Core

Does the operator's submitted photograph No. 14 (one hose crane hoist winch, the stowed wire and the limit switches) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe hoist wire is greased and undamaged, spooled correctly, with a certificate; limit switches are tested and work.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain how often the wire is inspected and greased, and when it was last renewed
  • Describe how limit switches are tested before use and the record kept
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Wire rope certificate
  • Limit switch test records
  • Crane PMS records

11.1.15 Starboard manifold looking from aft to forward Core

Does the operator's submitted photograph No. 15 (the starboard cargo manifold looking from aft towards forward) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe starboard manifold matches the photo: blanks fully bolted, drip tray clean, gauges calibrated and coating maintained.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain the manifold maintenance routine and pressure gauge calibration
  • Point out the blank flanges fully bolted and drip tray kept clean and empty
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Pressure gauge calibration records
  • Manifold pipe pressure test records
  • PMS records for manifold valves

11.1.16 Starboard manifold looking forward to aft Core

Does the operator's submitted photograph No. 16 (the starboard cargo manifold looking from forward towards aft) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe starboard manifold matches the photo: blanks fully bolted, drip tray clean, gauges calibrated and coating maintained.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain the manifold maintenance routine and pressure gauge calibration
  • Point out the blank flanges fully bolted and drip tray kept clean and empty
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Pressure gauge calibration records
  • Manifold pipe pressure test records
  • PMS records for manifold valves

11.1.17 Aft main deck showing condition of deck (and external framing) Core

Does the operator's submitted photograph No. 17 (the aft main deck, showing deck condition and any external framing) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe aft main deck matches the photo: coating maintained, framing sound, walkways and fittings in good order.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain the deck maintenance plan and progress of chipping/painting
  • Point out any repaired areas and show the records
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Deck maintenance/painting plan and records
  • Defect reports for structure
  • Class survey records

11.1.18 Aft main deck showing condition of Piperack Core

Does the operator's submitted photograph No. 18 (the aft main deck pipe rack) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe aft pipe rack matches the photo: pipes and supports coated and sound, no temporary repairs, lines tested and recorded.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain how pipelines are inspected and pressure tested under the PMS
  • Show records for any pipe renewal or repair and confirm no temporary repairs exist
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Pipeline pressure test records
  • PMS records for deck pipelines
  • Defect reports for pipe rack

11.1.19 Poop deck looking from midships to starboard including fairleads Core

Does the operator's submitted photograph No. 19 (the poop deck seen from midships towards starboard, including the fairleads) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe poop deck matches the photo: fairleads and rollers free, deck coated, mooring area tidy and equipment maintained.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain the inspection and greasing routine for aft mooring fittings
  • Point out any recent repairs and show the record
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • PMS records for mooring fittings
  • Mooring equipment records
  • Defect reports for aft deck

11.1.20 Aft emergency towing equipment storage arrangement Core

Does the operator's submitted photograph No. 20 (the stowage arrangement for the aft emergency towing equipment) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe aft emergency towing gear is stowed and protected as in the photo, inspected regularly and backed by the ship's towing procedure.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain what the aft emergency towing equipment consists of and how it is stowed
  • Show the periodic inspection records and the ship-specific emergency towing procedure
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Emergency towing booklet / procedure
  • Inspection records for towing equipment
  • Equipment manufacturer's instructions

11.1.21 Aft emergency towing equipment deployment system Core

Does the operator's submitted photograph No. 21 (the aft emergency towing deployment arrangement) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe aft towing gear deploys as described in the ship's procedure; route clear, release free and drills recorded.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain how the aft towing gear is deployed: release, run the messenger, pick-up line passed to the towing vessel
  • Show the drill or deployment exercise records
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Emergency towing booklet / procedure
  • Drill records
  • PMS records of strongpoint and fairlead inspection

11.1.22 Lifeboat and davit Core

Does the operator's submitted photograph No. 22 (a lifeboat and its davit) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe lifeboat and davit match the photo: condition sound, falls in date, release gear serviced and drills recorded.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain the lifeboat inspection routine: weekly and monthly checks, annual thorough examination and five-yearly overhaul of release gear and winch by an approved service provider
  • Show the falls renewal record and the last launching drill
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Weekly/monthly LSA inspection records
  • Annual and five-yearly service reports
  • Falls certificate and renewal records
  • Drill records

11.1.23 The emergency generator or accumulator batteries Core

Does the operator's submitted photograph No. 23 (the ship's emergency generator, or the battery set where batteries are the emergency source) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe emergency generator/battery room matches the photo: clean, ventilated, ready to run and tested on schedule.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain the weekly test and periodic on-load or blackout test routine
  • Point out starting instructions and fuel tank quick closing valve, or battery maintenance records
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Emergency generator/battery test records
  • PMS records
  • Starting instructions posted

11.1.24 Engine room general view showing top of main engine Core

Does the operator's submitted photograph No. 24 (a general engine room view showing the top of the main engine) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe engine room top matches the photo: clean, no leaks, hot surfaces insulated and no loose items.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain the housekeeping routine and how leaks are found and repaired
  • Show any open defect for leaks and the planned repair
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Defect reports
  • PMS records
  • Engine room cleaning schedule

11.1.25 One generator engine Core

Does the operator's submitted photograph No. 25 (one generator engine) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe generator matches the photo: clean, leak-free, insulated, gauges working and maintenance current.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain the generator overhaul schedule based on running hours and when the last overhaul was done
  • Show any open defects and the repair plan
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Generator PMS records and running hours
  • Lube oil analysis reports
  • Defect reports

11.1.26 The oil filtering equipment Core

Does the operator's submitted photograph No. 26 (the oily water separator and its 15 ppm monitoring equipment) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe separator and 15 ppm meter match the photo, with no bypass possible; calibration, alarm test and ORB entries are in order.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain how the separator and 15 ppm alarm work and how the automatic stopping device is tested
  • Show the Oil Record Book entries and that the piping matches the approved drawing
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • IOPP certificate and supplement
  • Oil Record Book Part I
  • Oil content meter calibration certificate
  • Seal log for overboard valve

11.1.27 The incinerator Core

Does the operator's submitted photograph No. 27 (the incinerator) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe incinerator matches the photo: clean, safe, instructions posted and use correctly recorded in the record books.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain the operating procedure: what may and may not be burned, and the restrictions in port or special areas
  • Show records of incinerator use and maintenance
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Incinerator type approval certificate
  • Garbage Record Book and Oil Record Book entries
  • PMS records

11.1.28 One boiler from the front Core

Does the operator's submitted photograph No. 28 (one boiler seen from the front) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe boiler front matches the photo: clean, no leaks, gauge glasses clear and safety devices tested and recorded.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain the boiler safety device test routine (low level trips, flame failure) and how it is recorded
  • Show boiler water test records and treatment
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Boiler safety device test records
  • Boiler water test log
  • PMS records

11.1.29 One boiler from the top showing control equipment Core

Does the operator's submitted photograph No. 29 (one boiler seen from the top, showing the control equipment) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe boiler top matches the photo: controls and safety valves in good order, no leaks and tests recorded.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain the safety devices and control instruments on top of the boiler and their test intervals
  • Show records of safety valve settings and surveys
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Safety valve setting records and survey reports
  • Boiler control test records
  • Defect reports

11.1.30 Purifier room general view Core

Does the operator's submitted photograph No. 30 (a general view of the purifier room) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe purifier room matches the photo: clean, leak-free, fire protection working and door closing properly.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain the purifier maintenance and cleaning routine
  • Point out the fire protection arrangements and how they are tested
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Purifier PMS records
  • Fire detection/local application system test records
  • Defect reports

11.1.31 Main engine side showing local control station Core

Does the operator's submitted photograph No. 31 (the side of the main engine showing the local control station) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe main engine local control station matches the photo: working indicators and telegraph, instructions posted and tests recorded.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain how you change over to local control and communicate with the bridge
  • Show records of the local control tests
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Local control test records
  • Posted instructions
  • Engine side condition

11.1.32 Steering gear room general view showing access Core

Does the operator's submitted photograph No. 32 (a general view of the steering gear room including its access) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe steering gear room matches the photo: clean, access clear, instructions posted and emergency steering drills recorded.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain the emergency steering procedure and drill frequency
  • Show that the room is kept clear and not used for storage
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Emergency steering drill records
  • Posted instructions and diagram
  • Steering gear PMS records

11.1.33 Main steering gear Core

Does the operator's submitted photograph No. 33 (the main steering gear) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe steering gear matches the photo: no leaks, oil levels correct, greased, and tested before every departure.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain the pre-departure test routine and alarms
  • Show hydraulic oil analysis and maintenance records
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Steering gear test records
  • Hydraulic oil analysis reports
  • PMS records

11.1.40 IG system pressure/vacuum-breaking (P/V) device Core

Does the operator's submitted photograph No. 40 (the inert gas pressure/vacuum breaker) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe P/V breaker matches the photo: correct liquid level, clean outlet and inspected regularly as part of the IG system.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain the purpose: prevents over- or under-pressure of the cargo tanks if the P/V valves fail
  • Show how the liquid level is checked and topped up and the record
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • P/V breaker inspection records
  • PMS records
  • IG system manual

11.1.41 IG system first non-return device (deck seal or double block and bleed arrangement) Core

Does the operator's submitted photograph No. 41 (the primary IG back-flow barrier, i.e. the deck water seal or DBB valve set) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe deck water seal (or DBB valves) matches the photo: level and alarms working, no corrosion, inspected regularly.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain how the deck water seal (or DBB valve set) prevents back-flow of cargo vapours to the machinery spaces
  • Show the test records of water level alarms or valve operation
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Deck seal level alarm test records
  • IG system PMS records
  • IG system manual

11.1.42 One main cargo pump and, if in pump room, including bilges Core

Does the operator's submitted photograph No. 42 (a main cargo pump, plus the bilges if that pump sits in a pump room) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe cargo pump matches the photo: no leaks, temperature sensors working and pump room bilges clean and dry.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain the pump inspection routine: seal leaks, bearing temperatures and bulkhead seal checks
  • Show that pump room bilges are kept dry and bilge alarms tested
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Cargo pump PMS records
  • Pump room gas detection and bilge alarm test records
  • Bearing temperature records

11.1.50 A cargo tank liquid dome including load and discharge valve Core

Does the operator's submitted photograph No. 50 (the liquid dome of one cargo tank, with its loading and discharge valves) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe liquid dome matches the photo: valves and insulation in good order, ESD tested and no leaks or corrosion.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain the valve maintenance and ESD testing routine for LPG cargo valves
  • Point out any insulation repairs and the defect record
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Cargo valve PMS records
  • ESD test records
  • Defect reports

11.1.51 Electric motors for deepwell pumps Core

Does the operator's submitted photograph No. 51 (the electric motors of the deepwell cargo pumps) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe deepwell pump motors match the photo: sound casings, sealed glands, greased bearings and insulation tests recorded.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain the motor maintenance routine: insulation resistance tests, bearing greasing
  • Show any condition monitoring results and records
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Motor PMS records
  • Insulation resistance test records
  • Condition monitoring reports

11.1.52 Compressor / motor room Core

Does the operator's submitted photograph No. 52 (the compressor room / electric motor room) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe compressor and motor rooms match the photo: clean, seals and air locks working, gas detection and ventilation tested.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain the compressor maintenance routine and gas detection checks
  • Show air lock alarm and ventilation test records
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Compressor PMS records
  • Gas detection calibration records
  • Air lock door alarm test records

11.1.60 A cargo tank liquid dome including load and discharge valve Core

Does the operator's submitted photograph No. 60 (the liquid dome of one cargo tank, with its loading and discharge valves) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe liquid dome matches the photo: valves and insulation in good order, ESD tested and no leaks or corrosion.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain the valve maintenance and ESD testing routine for LPG cargo valves
  • Point out any insulation repairs and the defect record
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Cargo valve PMS records
  • ESD test records
  • Defect reports

11.1.61 Electric motors for deepwell pumps Core

Does the operator's submitted photograph No. 61 (the electric motors of the deepwell cargo pumps) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe deepwell pump motors match the photo: sound casings, sealed glands, greased bearings and insulation tests recorded.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain the motor maintenance routine: insulation resistance tests, bearing greasing
  • Show any condition monitoring results and records
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Motor PMS records
  • Insulation resistance test records
  • Condition monitoring reports

11.1.62 Compressor room internal view Core

Does the operator's submitted photograph No. 62 (an internal view of the compressor room) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe compressor room matches the photo: clean, no leaks, ventilation and gas detection working and tested.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain the compressor maintenance routine and gas detection checks
  • Show ventilation and gas detection test records
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Compressor PMS records
  • Gas detection calibration records
  • Ventilation system test records

11.1.70 A cargo tank liquid dome including load and discharge valve Core

Does the operator's submitted photograph No. 70 (the liquid dome of one cargo tank, with its loading and discharge valves) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe liquid dome matches the photo: valves and insulation in good order, ESD tested and no leaks or corrosion.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain the valve maintenance and ESD testing routine for LNG cargo valves
  • Point out any insulation repairs and the defect record
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Cargo valve PMS records
  • ESD test records
  • Defect reports

11.1.71 A cargo tank vapour dome including cargo system relief valves Core

Does the operator's submitted photograph No. 71 (the vapour dome of one cargo tank, with the relief valves of the cargo system) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe vapour dome matches the photo: relief valves in date and set correctly, insulation intact, no corrosion.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain how relief valve settings are verified and recorded
  • Point out any defects and repair records
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Relief valve test and setting records
  • Defect reports
  • PMS records

11.1.72 Compressor house internal view Core

Does the operator's submitted photograph No. 72 (an internal view of the compressor house) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe compressor house matches the photo: clean, no leaks, ventilation and gas detection working and tested.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain the compressor maintenance routine and gas detection checks
  • Show ventilation and gas detection test records
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Compressor PMS records
  • Gas detection calibration records
  • Ventilation system test records

11.1.80 A cargo tank liquid dome including load and discharge valve Core

Does the operator's submitted photograph No. 80 (the liquid dome of one cargo tank, with its loading and discharge valves) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe liquid dome matches the photo: valves and insulation in good order, ESD tested and no leaks or corrosion.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain the valve maintenance and ESD testing routine for LNG cargo valves
  • Point out any insulation repairs and the defect record
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Cargo valve PMS records
  • ESD test records
  • Defect reports

11.1.81 General view of one moss sphere Core

Does the operator's submitted photograph No. 81 (a general view of one Moss sphere) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe Moss sphere cover matches the photo: coating maintained, seals intact and inspections recorded.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain the tank cover inspection and coating maintenance routine
  • Show records of any repairs
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Tank cover PMS records
  • Defect reports
  • Class survey records

11.1.82 Compressor house internal view Core

Does the operator's submitted photograph No. 82 (an internal view of the compressor house) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe compressor house matches the photo: clean, no leaks, ventilation and gas detection working and tested.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain the compressor maintenance routine and gas detection checks
  • Show ventilation and gas detection test records
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Compressor PMS records
  • Gas detection calibration records
  • Ventilation system test records

11.1.90 Bow mooring arrangement from forward looking aft showing chain stopper Core

Does the operator's submitted photograph No. 90 (the bow loading mooring arrangement seen from forward looking aft, showing the chain stopper) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe bow chain stopper matches the photo: locking mechanism working, no leaks and tests recorded.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain the chain stopper inspection and test routine
  • Show the stopper load test and maintenance records
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Bow loading system PMS records
  • Chain stopper test records
  • Maker's maintenance instructions

11.1.91 Bow mooring arrangement from aft looking forward showing winch Core

Does the operator's submitted photograph No. 91 (the bow loading mooring arrangement seen from aft looking forward, showing the winch) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe bow loading winch matches the photo: brake tested, no leaks and messenger lines in good condition.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain winch maintenance and brake testing
  • Show the condition of messenger lines and replacement records
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Bow loading winch PMS records
  • Brake test records
  • Messenger line records

11.1.92 General view of hose connection area Core

Does the operator's submitted photograph No. 92 (a general view of the bow loading hose connection area) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe hose connection area matches the photo: clean, drip tray drained, gas detection and fire-fighting ready.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain the bow loading area inspection routine
  • Point out fire-fighting and gas detection arrangements
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Bow loading system PMS records
  • Gas detection test records
  • Fire-fighting equipment inspection records

11.1.93 Hose coupling arrangement Core

Does the operator's submitted photograph No. 93 (the bow loading hose coupling) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe hose coupler matches the photo: seals and jaws in good condition, emergency release tested before every loading.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain the coupler and emergency release test routine before each loading
  • Show maintenance and seal renewal records
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Coupler PMS and test records
  • Emergency release test records
  • Maker's instructions

11.1.94 General view forward bow thruster room Core

Does the operator's submitted photograph No. 94 (a general view of the forward bow thruster room) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe bow thruster room matches the photo: clean, dry bilges, no leaks and alarms tested.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain the thruster room inspection routine and bilge alarm tests
  • Show any open defects and repair plans
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Thruster room PMS records
  • Bilge alarm test records
  • Defect reports

11.1.95 Forward bow thruster room showing one azimuth thruster Core

Does the operator's submitted photograph No. 95 (one azimuth thruster in the forward thruster room) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe azimuth thruster matches the photo: no leaks, oil levels correct and tested before DP or bow loading operations.

How to answer
  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain the thruster test routine before DP or bow loading operations
  • Show oil analysis and maintenance records
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
Have ready
  • The submitted photograph and the same viewpoint on board
  • Thruster PMS records
  • Oil analysis reports
  • DP/thruster test records

An independent guide written by seafarers for seafarers. It is not affiliated with or endorsed by OCIMF and does not reproduce the SIRE 2.0 Question Library: questions are put in our own words. The official library and guidance are published by OCIMF (ocimf.org). Always follow your company's SMS.