11.1.25 One generator engine
CoreChemicalLNGLPGOilWhere: Engine Room
Does the operator's submitted photograph No. 25 (one generator engine) match what the inspector actually sees on board on the day, and is that area free from anything of concern?
In one lineThe generator matches the photo: clean, leak-free, insulated, gauges working and maintenance current.
How to answer
- Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
- Explain the generator overhaul schedule based on running hours and when the last overhaul was done
- Show any open defects and the repair plan
- If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
What the inspector looks for
- Whether the submitted photo is a true, current picture of the area
- Engine clean, no fuel, lube or water leaks
- Hot surfaces insulated, HP fuel pipes jacketed
- Gauges working, guards fitted
- Running hours and maintenance up to date
Have ready to show
- The submitted photograph and the same viewpoint on board
- Generator PMS records and running hours
- Lube oil analysis reports
- Defect reports
Avoid
- A photo that shows a better condition than the area actually has on the day
- Leaks, oil-soaked lagging or missing guards
- Defective gauges
Practise in the interview trainer All questions
An independent guide written by seafarers for seafarers. It is not affiliated with or endorsed by OCIMF and does not reproduce the SIRE 2.0 Question Library: questions are put in our own words. The official library and guidance are published by OCIMF (ocimf.org). Always follow your company's SMS.