11.1.26 The oil filtering equipment

CoreChemicalLNGLPGOilWhere: Engine Room

Does the operator's submitted photograph No. 26 (the oily water separator and its 15 ppm monitoring equipment) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe separator and 15 ppm meter match the photo, with no bypass possible; calibration, alarm test and ORB entries are in order.

How to answer

  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain how the separator and 15 ppm alarm work and how the automatic stopping device is tested
  • Show the Oil Record Book entries and that the piping matches the approved drawing
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record

What the inspector looks for

  • Whether the submitted photo is a true, current picture of the area
  • Separator and oil content meter in good condition and not modified
  • Piping arrangement as per IOPP certificate supplement, no unapproved bypass connections
  • Oil content meter calibration and 15 ppm alarm test records
  • Overboard valve seals and Oil Record Book entries

Have ready to show

  • The submitted photograph and the same viewpoint on board
  • IOPP certificate and supplement
  • Oil Record Book Part I
  • Oil content meter calibration certificate
  • Seal log for overboard valve

Avoid

  • A photo that shows a better condition than the area actually has on the day
  • Unapproved connections or flexible hoses that could bypass the separator
  • Oil content meter out of calibration

Practise in the interview trainer All questions