11.1.28 One boiler from the front
CoreChemicalLNGLPGOilWhere: Engine Room
Does the operator's submitted photograph No. 28 (one boiler seen from the front) match what the inspector actually sees on board on the day, and is that area free from anything of concern?
In one lineThe boiler front matches the photo: clean, no leaks, gauge glasses clear and safety devices tested and recorded.
How to answer
- Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
- Explain the boiler safety device test routine (low level trips, flame failure) and how it is recorded
- Show boiler water test records and treatment
- If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
What the inspector looks for
- Whether the submitted photo is a true, current picture of the area
- Burner area clean, no fuel leaks, insulation intact
- Gauge glasses clear and readable, water level visible
- Safety valves and easing gear in order
- Boiler water test records
Have ready to show
- The submitted photograph and the same viewpoint on board
- Boiler safety device test records
- Boiler water test log
- PMS records
Avoid
- A photo that shows a better condition than the area actually has on the day
- Fuel leaks or soot around the burner
- Unreadable gauge glasses
Practise in the interview trainer All questions
An independent guide written by seafarers for seafarers. It is not affiliated with or endorsed by OCIMF and does not reproduce the SIRE 2.0 Question Library: questions are put in our own words. The official library and guidance are published by OCIMF (ocimf.org). Always follow your company's SMS.