11.1.29 One boiler from the top showing control equipment
CoreChemicalLNGLPGOilWhere: Engine Room
Does the operator's submitted photograph No. 29 (one boiler seen from the top, showing the control equipment) match what the inspector actually sees on board on the day, and is that area free from anything of concern?
In one lineThe boiler top matches the photo: controls and safety valves in good order, no leaks and tests recorded.
How to answer
- Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
- Explain the safety devices and control instruments on top of the boiler and their test intervals
- Show records of safety valve settings and surveys
- If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
What the inspector looks for
- Whether the submitted photo is a true, current picture of the area
- Control equipment, sensors and wiring in good condition
- Safety valve exhaust pipes and drains in order
- No steam or water leaks, insulation intact
- Access clear and well lit
Have ready to show
- The submitted photograph and the same viewpoint on board
- Safety valve setting records and survey reports
- Boiler control test records
- Defect reports
Avoid
- A photo that shows a better condition than the area actually has on the day
- Steam leaks or damaged insulation
- Damaged wiring or sensors