11.1.41 IG system first non-return device (deck seal or double block and bleed arrangement)
CoreChemicalOilWhere: Main Deck
Does the operator's submitted photograph No. 41 (the primary IG back-flow barrier, i.e. the deck water seal or DBB valve set) match what the inspector actually sees on board on the day, and is that area free from anything of concern?
In one lineThe deck water seal (or DBB valves) matches the photo: level and alarms working, no corrosion, inspected regularly.
How to answer
- Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
- Explain how the deck water seal (or DBB valve set) prevents back-flow of cargo vapours to the machinery spaces
- Show the test records of water level alarms or valve operation
- If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record
What the inspector looks for
- Whether the submitted photo is a true, current picture of the area
- Deck water seal level correct and alarms working, or DBB valves and vent in good order
- Heating coils working in cold climates
- Corrosion and leaks
- Inspection and maintenance records
Have ready to show
- The submitted photograph and the same viewpoint on board
- Deck seal level alarm test records
- IG system PMS records
- IG system manual
Avoid
- A photo that shows a better condition than the area actually has on the day
- Low water level or defective alarms
- Corroded deck seal body