Does the operator's submitted photograph No. 51 (the electric motors of the deepwell cargo pumps) match what the inspector actually sees on board on the day, and is that area free from anything of concern?

In one lineThe deepwell pump motors match the photo: sound casings, sealed glands, greased bearings and insulation tests recorded.

How to answer

  • Before the inspection, stand at the same viewpoint as the submitted photo and compare it with the area today
  • Explain the motor maintenance routine: insulation resistance tests, bearing greasing
  • Show any condition monitoring results and records
  • If the area has changed since the photo (repairs, new coating, equipment replaced), explain the change and show the record

What the inspector looks for

  • Whether the submitted photo is a true, current picture of the area
  • Motor condition, coating and corrosion
  • Cable glands and terminal boxes sealed
  • Bearing lubrication and condition monitoring
  • Shaft seal arrangement free of leaks

Have ready to show

  • The submitted photograph and the same viewpoint on board
  • Motor PMS records
  • Insulation resistance test records
  • Condition monitoring reports

Avoid

  • A photo that shows a better condition than the area actually has on the day
  • Corroded motor casings
  • Damaged cable glands

Practise in the interview trainer All questions