5.2.7 Fire pumps, fire main, fire main isolating valves and fire hydrants
Rotational 1ChemicalLNGLPGOilAsked to: Master, Chief Officer, 2nd / 3rd Officer, Engineer officersWhere: Bridge, Emergency Headquarters., Engine Room, Exterior Decks
Are the Master and officers familiar with where the fire pumps, fire main, isolating valves and hydrants are, what they do and how to operate them, and is the whole system in good condition and ready for immediate use?
In one lineFire pumps start locally and remotely; isolating valves and drains are known and marked; hydrants and main are in good order.
How to answer
- Explain how the main fire pumps are started locally and remotely and how pressure is confirmed
- Show the isolating valves and explain why the deck main can be isolated from the machinery space
- Show where the deck fire main drains are and explain draining in cold weather
- Explain the inspection/test routine for hydrants and valves
- Describe how damaged sections of fire main are isolated
What the inspector looks for
- Ability to start fire pumps from local and remote positions
- Location and function of isolating valves (e.g. between engine room and deck)
- Condition of fire main and hydrants (corrosion, leaks, missing handwheels)
- Drain arrangements on deck fire main to prevent freezing
- Pressure test and maintenance records
Have ready to show
- Fire pumps and remote start positions
- Isolating valves on fire main
- Fire main drains
- Hydrants with hoses
- PMS records
- Fire main pressure test records
Avoid
- Leaking hydrants or fire main with temporary repairs
- Isolating valves unmarked or crew unsure of their purpose
- Crew unable to start fire pumps
- Fire main drains seized or left closed in freezing weather