SeaVint

Chapter 5. Safety management

88 questions with how to answer each.

5.1.1 Records of mandatory and company defined emergency drills Core

Do the Master and officers know the ship's emergency response plans, and can the ship prove with records that every drill required by regulation and by the company has been carried out and logged as the SMS requires?

In one lineAll mandatory and company drills are on a planner, done on time, recorded with lessons learned, and reflected in rest hour records.

How to answer
  • Explain how a drill is planned: scenario chosen from the drill matrix, briefing, realistic exercise, debrief and lessons learned
  • Describe how the record is made: drill form/logbook entry, attendance list, equipment tested, observations and corrective actions
  • Explain what happens when a drill cannot be done on time (e.g. cargo operations): report to the office, record the reason, carry it out at the first opportunity
  • State that drill time is entered as work time in the rest hour records and that drills are planned to minimise disturbance of rest, with compensatory rest given where rest was interrupted
  • Name the monthly SOLAS minimum (abandon ship and fire drill for every crew member) and the two-monthly enclosed space rescue drill
Have ready
  • Annual/quarterly drill planner and drill matrix
  • Completed drill records and debrief notes
  • Official logbook / deck log entries for drills
  • Work and rest hour records covering drill dates
  • Training manual and muster list
  • Emergency response manual / contingency plans

5.1.2 Emergency plans & drills for principal fire scenarios Rotational 1

Do the Master and officers know the ship's emergency plans for the main fire risks on this type of tanker or gas carrier, and have drills been held to test whether those plans work as the company requires?

In one lineI know my fire duty, the first actions for each main fire scenario, and our drills rotate through engine room, cargo area and accommodation.

How to answer
  • State your muster station and your role (e.g. leader of fire party, boundary team, emergency HQ, first aid)
  • Walk through the first actions: raise alarm, stop cargo/bunker operations, close ventilation and dampers, muster, head count, isolate fuel/power
  • Explain how fixed systems would be used for a machinery space fire and the head-count before release
  • Describe boundary cooling and communication between on-scene leader and bridge/CCR
  • Mention the most recent fire drill scenario and one lesson learned from it
Have ready
  • Muster list and emergency duty cards
  • Fire control plan (posted and the copy outside the accommodation)
  • Fire drill records with varied scenarios
  • Emergency response plans for each fire scenario
  • Firemen's outfits and fire locker
  • Debrief and corrective action records

5.1.3 Pollution prevention drills required by SOPEP or SMPEP Rotational 1

Do the Master and officers know the ship's oil (SOPEP) or noxious liquid (SMPEP) pollution emergency plan, and have drills been held to check that the response actions in the plan and company procedures actually work?

In one lineStop, contain, report: I know my SOPEP/SMPEP duties, where the spill kit is, and the reporting chain from the plan.

How to answer
  • Explain your duty in a spill: raise alarm, stop operation, notify the OOW/CCR, plug scuppers, contain and clean up with SOPEP gear
  • Describe the initial reporting chain: Master, company, coastal state/port authority, terminal; contact lists are in the plan's appendices
  • Explain checking that scuppers are plugged and drip trays empty before cargo or bunker operations
  • State that only intrinsically safe cameras and equipment are used in the cargo area to record the incident
  • Give the scenario and outcome of the last pollution drill
Have ready
  • SOPEP / SMPEP (or combined SMPEP) with up-to-date contact list
  • SOPEP locker and inventory checklist
  • Pollution drill records
  • Intrinsically safe camera
  • Oil Record Book / Cargo Record Book
  • Scupper plugs and deck containment arrangements

5.1.4 Enclosed space rescue emergency response drill Rotational 1

Is the Master and officers' knowledge of the enclosed space rescue plan adequate, and have rescue drills been carried out to prove the plan works as the company procedure requires?

In one lineAttendant never enters: raise alarm, keep contact, ready gear; rescue team enters only with BA, tests atmosphere and lifts casualty with the stretcher.

How to answer
  • Explain the attendant's role: stay at the entrance, raise the alarm, do not enter, keep talking to those inside, prepare equipment, brief the rescue team
  • Walk the inspector through rigging the rescue tripod or hoist, the harness and lifeline, and lifting with the stretcher
  • Describe actions if someone collapses inside: alarm, muster rescue team, ventilation increased, SCBA donned, atmosphere tested, casualty supplied with air and lifted
  • Explain that no one enters to rescue without breathing apparatus
  • Name the rescue equipment stored at the location and the date of the last enclosed space drill
Have ready
  • Rescue tripod/hoist and its inspection record
  • Rescue stretcher (e.g. Sked or Neil Robertson type)
  • SCBA sets, spare cylinders, EEBDs
  • Portable gas detectors with calibration records
  • Enclosed space rescue drill records
  • Enclosed space entry permits used in drills

5.1.5 Drills required by the Ship Security Plan (SSP) Rotational 1

Are the Master and Ship Security Officer familiar with the Ship Security Plan, and have security drills been carried out to test the measures and procedures it contains?

In one lineSecurity drills every three months (extra after major crew change), annual exercise, varied scenarios, recorded; SSP stays confidential.

How to answer
  • Explain the drill frequency: at least every three months, and an additional drill within one week if more than 25% of the crew changed and they have not drilled on this ship in the last three months
  • State that an exercise involving company/port is done at least once each calendar year with no more than 18 months between them
  • Describe the last drill scenario and what was improved
  • Explain how the SSAS is tested and the access control measures at each security level
  • Keep the SSP confidential: offer to show records, not the restricted sections
Have ready
  • Security drill and exercise records
  • Declaration of Security records where relevant
  • Security log / gangway visitor log
  • SSAS test records
  • International Ship Security Certificate
  • Security training records of crew

5.1.6 Launching the lifeboat(s) and abandon ship drills Rotational 1

Do the Master, officers and ratings know how to launch the lifeboat(s), and have abandon ship drills been held in line with company procedures, SOLAS and flag requirements?

In one lineMonthly abandon ship drills, boat launched and manoeuvred at least every three months, and I can explain each launching step.

How to answer
  • Walk through launching: remove gripes and harbour pins, check the area below, crew embark, release brake from inside or locally, lower, release hooks once waterborne
  • State the drill frequency and when the boat was last launched and manoeuvred
  • Explain the hydrostatic interlock and the on-load release procedure and its dangers
  • Explain abandon ship signal, muster station, lifejacket and immersion suit donning
  • Describe any feedback from the last drill and how it was closed
Have ready
  • Abandon ship drill records
  • Lifeboat launch records
  • Muster list and lifeboat embarkation instructions
  • Operating instructions posted at the boat
  • Training manual
  • Weekly/monthly LSA inspection checklists

5.1.7 Emergency plan & drills for a cargo vapour or liquid release, Including potential fire Rotational 1

On gas carriers, do the Master and officers know the emergency plan for a release of cargo vapour or liquid (including a possible fire), and have drills been held to test that plan?

In one lineAlarm, ESD, stop cargo, water spray/curtain, secure accommodation, control ignition, PPE against cold and toxic exposure.

How to answer
  • Describe immediate actions: sound alarm, activate ESD, stop cargo operations, inform terminal, start water spray/water curtain
  • Explain how ignition sources are controlled and the accommodation is secured
  • Describe PPE for cold liquid and toxic cargoes and use of breathing apparatus
  • Explain how dry powder and water spray would be used if the leak ignites, and boundary cooling
  • Give the last drill scenario and its findings
Have ready
  • Emergency response plan for cargo release
  • ESD system test records
  • Water spray system test records
  • Drill records
  • Cargo data sheets / SDS for cargo on board
  • Cryogenic PPE and BA sets

5.1.8 Emergency plan & drills for collision Rotational 2

Do the Master and officers know the ship's collision emergency plan, and have drills been held to check that it works as the company procedures require?

In one lineAlarm, stop/manoeuvre, close WT doors, muster, sound tanks, assess stability, prevent pollution and fire, report.

How to answer
  • Explain immediate actions: general alarm, engines as required, close watertight doors, muster and head count, VHF/DSC to the other ship and VTS
  • Describe damage assessment: sounding all tanks and voids, checking cargo ullages, IG pressure, gas detection
  • Explain how stability and stress are assessed, including contact with the shore damage stability service
  • Describe short/medium-term steps: limit pollution, transfer cargo if needed, prepare fire teams, report to the company and coastal state
  • Mention the last collision drill and what was learnt
Have ready
  • Collision emergency checklist
  • Shipboard Emergency Response Manual
  • Shore-based emergency response service details
  • Loading computer with damage stability
  • SOPEP/SMPEP
  • Drill records

5.1.9 Emergency plan & drills for grounding Rotational 2

Do the Master and officers know the grounding emergency plan, and have drills tested its effectiveness as required by the company?

In one lineStop engines, alarm, signals, sound around and all tanks, assess stability before refloating, prevent pollution, report.

How to answer
  • Describe immediate actions: stop engines, sound alarm, display aground signals, check for injuries, close WT doors
  • Explain sounding around the ship to find the grounding position and tank soundings to find breaches
  • Explain that no refloating attempt is made until stability and hull stress are assessed and the company/salvors consulted
  • Mention the shore-based damage stability service required for oil tankers and SOPEP reporting
  • Describe tidal and weather considerations and ballast/cargo transfer to reduce ground reaction
Have ready
  • Grounding emergency checklist
  • Emergency response manual
  • Loading computer / damage stability tools
  • Tide tables and charts
  • SOPEP/SMPEP
  • Drill records

5.1.10 Emergency plan & drills for loss of propulsion Rotational 2

Do the Master and officers know what the emergency plan says to do if propulsion is lost, and have drills been held to prove the plan works as the company requires?

In one lineShow NUC, warn traffic, inform VTS and company, plot drift from wind and current, prepare anchors and towing early.

How to answer
  • Explain immediate actions: inform Master and engine room, exhibit NUC lights/shapes, broadcast warning, inform VTS/coastal state
  • Explain how drift is estimated: plot wind and current vectors and leeway (from ship's data or experience), plot successive positions to confirm
  • Describe when to prepare anchors (depth permitting) and emergency towing
  • Explain notification to company and the decision point for requesting tug assistance
  • Mention the date and scenario of the last drill
Have ready
  • Loss of propulsion checklist
  • Bridge procedures manual
  • Emergency towing booklet
  • Charts with drift plots from drills
  • Drill records
  • Engine log of the drill

5.1.11 Emergency plan & drills for failure of electrical power Rotational 2

Do the Master and officers know the emergency plan for electrical power failure (blackout), and have drills tested it according to company procedures?

In one lineEmergency generator starts automatically, transitional power bridges the gap; we find the cause, restore main power and essential services in sequence.

How to answer
  • Show where the blackout procedure is kept (engine control room and bridge)
  • Explain the sequence: emergency generator starts automatically and supplies the emergency switchboard, transitional battery source covers the gap
  • Describe restoring main power: find cause, start generators, reconnect preferential loads, restart steering, lubricating and cooling pumps, then main engine
  • Explain bridge actions: NUC signals, inform VTS, steering on emergency power
  • State when the emergency generator was last tested on load
Have ready
  • Blackout recovery procedure
  • Emergency generator test records
  • Emergency switchboard and battery room
  • Engine log of drills
  • Drill records
  • Emergency lighting test records

5.1.12 Steering gear failure emergency drill Rotational 2

Do the Master and officers know the emergency plan for a steering gear failure, and have drills been carried out to prove it works under the company's procedures?

In one lineEmergency steering drill every three months; I can change to local control, communicate with the bridge and follow helm orders.

How to answer
  • Demonstrate local control in the steering gear room: change over to local, operate the solenoid buttons or trick wheel, follow helm orders
  • Explain communications: sound-powered telephone or dedicated means, and the heading/rudder indication in the steering room
  • Describe the alternative or emergency power supply to the steering gear
  • Explain bridge actions: NUC, warn traffic, reduce speed, estimate drift
  • Give the date of the last emergency steering drill and logbook entry
Have ready
  • Changeover procedure and block diagram
  • Emergency steering drill records and log entries
  • Pre-departure steering gear test records
  • Communication equipment in steering gear room
  • Steering gear maintenance records
  • Gyro repeater/rudder indicator in steering room

5.1.13 Emergency plan & drills for emergency towing Rotational 2

Do the Master and officers know the emergency towing plan, including the ship-specific Emergency Towing Booklet, and have towing drills been carried out to test it?

In one lineETB on the bridge; aft gear deployable without power; I can explain rigging fore and aft and the safety precautions.

How to answer
  • Show where the ETB is kept (bridge, and copies as stated in the booklet) and explain its contents
  • Explain how to deploy the aft pick-up gear and towing pennant and how the forward arrangement is rigged
  • Explain how deployment works without main power (gravity or manual)
  • Describe safety precautions: snap-back zones, communication, PPE
  • Give the date of the last towing drill
Have ready
  • Emergency Towing Booklet
  • Emergency towing arrangements forward and aft
  • Maintenance records of towing gear
  • Drill records
  • Marking of strongpoints and fairleads

5.1.14 Man overboard emergency drill Rotational 2

Do the Master, officers and ratings know the man overboard plan, including how the rescue boat is launched and recovered, and have drills been held to show the plan works as the company requires?

In one lineShout, throw lifebuoy, MOB button, alarm, turn; rescue boat launched and recovered safely; I know my role.

How to answer
  • Explain immediate actions: shout and point, throw lifebuoy with light/smoke, press MOB on GPS/ECDIS, alarm, manoeuvre (e.g. Williamson turn)
  • Walk through rescue boat launching: crew in lifejackets/immersion suits, painter, engine start, lower, release, and recovery hooking-on
  • State your own role during MOB
  • Explain how the casualty is recovered and treated for hypothermia
  • Mention the last MOB drill
Have ready
  • Muster list
  • Rescue boat and launching appliance
  • MOB procedure
  • Drill records
  • Lifebuoys with lights and smoke signals
  • Rescue boat launching records

5.1.15 Emergency response plan & drills for recovery of persons from the water Rotational 2

Do the Master, officers and ratings know the ship's plan for getting people out of the water, and have drills been held to show that the plan works as the company procedure requires?

In one lineOur plan names the gear and positions; I know my role, we lift horizontally where possible and treat for hypothermia.

How to answer
  • Explain which recovery methods the plan uses on this ship and from which position
  • Describe your role: lookout, boat crew, recovery team at the side, first aid
  • Explain that a horizontal lift is preferred to reduce the risk of collapse from cold shock and hypothermia
  • Describe safety of the recovery team: lifejackets, harness, communications with the bridge, ship's lee side
  • State when the last recovery drill was held and what equipment was used
Have ready
  • Ship-specific plan for recovering people from the water
  • Recovery equipment (net, sling, stretcher, rescue boat)
  • Muster list showing recovery duties
  • Drill records
  • Medical guide / hypothermia treatment instructions

5.1.16 Emergency plans & drills for flooding Rotational 2

Do the Master and officers know the ship's emergency plans for flooding (engine room, pump room or hull breach), and have drills been run to prove those plans work as the company requires?

In one lineAlarm, find and isolate the source, pump out (emergency bilge suction if needed), sound all spaces, assess stability, report.

How to answer
  • Explain immediate actions: raise the alarm, inform bridge/ECR, find the source, close watertight doors and isolate sea valves or pipelines
  • Explain how water is removed: bilge and ballast pumps, and the engine room emergency bilge suction via the largest sea water pump
  • Describe how soundings of all tanks and voids are taken and stability and stress are checked on the loading computer
  • Explain reporting to the company and contact with the emergency response service if the hull is breached
  • Describe the last flooding drill, its scenario and lessons learned
Have ready
  • Flooding emergency checklists
  • Bilge and ballast system diagrams with emergency bilge suction marked
  • Loading computer / damage stability information
  • Bilge alarm and watertight door test records
  • Drill records

5.1.17 Emergency plans and drills for LNG bunker operations Rotational 2

On ships that receive LNG as fuel, do the Master and officers know the emergency plans covering LNG bunkering, and have drills been held to test those plans as the company requires?

In one lineESD, stop transfer, close valves, water curtain on, alarm and inform supplier; cryogenic PPE on; we drill it.

How to answer
  • Explain the fuel-handling manual's emergency actions: activate ESD, stop transfer, close manifold valves, sound alarm, inform the supplier
  • Describe how the water curtain protects the ship's side from brittle fracture and how drip trays collect any spill
  • Explain the gas detection and alarm/shutdown points in bunker station and fuel spaces
  • Describe cryogenic PPE (face shield, insulated gloves, apron) and first aid for cold burns
  • Mention the last LNG bunkering drill and whether the supplier was involved
Have ready
  • Fuel-handling manual (IGF Code) and bunkering procedure
  • Bunkering checklists, including the agreed ESD arrangements
  • ESD test records
  • Water curtain and drip tray arrangements
  • Cryogenic PPE
  • Drill records

5.1.18 Cargo leak into double hull spaces Rotational 2

On oil and chemical tankers, do the Master and officers know what the company requires them to do if cargo leaks into a ballast tank or void of the double hull, and is every item of equipment that procedure calls for on board and in good order?

In one lineDetect by gas/sounding, stop and isolate, monitor, inert and transfer cargo; never discharge contaminated ballast; equipment ready and listed.

How to answer
  • Explain how a leak would be found: rising gas readings in the double hull, unexpected ullage or sounding changes, product in ballast
  • Describe actions: stop cargo/ballast operations, isolate the affected ballast tank, monitor atmosphere, consider inerting and transferring cargo from the leaking tank
  • State that contaminated ballast is never discharged to sea and is handled as cargo residue
  • Walk the inspector to the equipment listed in the procedure and show its inventory/check record
  • Explain notification to the company and the terminal/port
Have ready
  • Company double-hull cargo leak procedure
  • Portable pump, hoses and inert gas connection where required
  • Double-hull gas monitoring records
  • Equipment inventory and inspection records
  • Oil Record Book Part II / Cargo Record Book

5.1.19 OBO Forward space emergency pumping arrangements Rotational 2

On combination carriers (OBO), do the Master and officers know the emergency means of pumping out flooded spaces ahead of the collision bulkhead, and are these arrangements clearly marked and in good working order?

In one lineI can explain and operate the forward space dewatering sequence; valves are marked, alarms work and the system is tested.

How to answer
  • Explain how the forward spaces are dewatered and from where the system is controlled
  • Walk through the sequence: open the correct suction and overboard valves, start the pump (or eductor), confirm suction, monitor levels
  • Show the markings and posted instructions at the control position
  • Explain the water ingress detection alarms and their testing
  • State when the system was last tested
Have ready
  • Operating instructions for forward space dewatering
  • Marked valves and controls
  • Pump/valve test records in the PMS
  • Water ingress alarm test records
  • Piping diagram

5.2.1 Emergency fire pump Core

Do the Master, officers and ratings know how to start the emergency fire pump, and do records show that the pump and its compartment have been maintained and tested as the company requires?

In one lineI can start the emergency fire pump locally and remotely; it is tested regularly and delivers pressure on deck.

How to answer
  • Explain the starting procedure step by step: open suction and delivery valves, check fuel/priming, start (electric, hydraulic or manual), confirm pressure
  • Show the remote start positions and explain any priming or isolation needed first
  • Explain the test routine: regular run with water on deck and pressure check at the most remote hydrant
  • Describe what to check before leaving the space: valves left in ready position, fuel topped up, area clean
  • State when it was last tested and the pressure obtained
Have ready
  • Emergency fire pump and its compartment
  • Operating instructions posted at the pump
  • PMS maintenance and test records
  • Fire and safety logbook / weekly test records
  • Remote start positions
  • Fuel tank for the emergency fire pump engine

5.2.2 Fire dampers & ventilation stops Rotational 1

Do the Master, officers and crew know where the fire dampers are, why they are fitted and how they are tested and operated, how the main ventilation inlets and outlets are closed, and how powered ventilation is stopped from outside the spaces it serves?

In one lineI know where the dampers and remote fan stops are, how to close them, how they're tested, and their positions during cargo work.

How to answer
  • Explain where the remote ventilation stops are (e.g. fire control station) and which fans each stops
  • Show how a damper is closed and how you confirm it is shut
  • Explain the testing interval and how it is recorded
  • Describe the positions during cargo operations: accommodation on recirculation where required and openings closed
  • Explain why closing ventilation is an early step in firefighting
Have ready
  • Fire control plan showing dampers and stops
  • Damper test records in the PMS
  • Remote stop panel
  • Marked damper handles
  • Ventilation closing appliances

5.2.3 Fixed fire detection and fire alarm system Rotational 1

Do the Master and officers understand where the fixed fire detection and alarm system and its panels are, what the system protects and how it works, and is it in good working order with regular inspection, testing and maintenance?

In one lineI can read the panel; all detectors are tested in rotation; isolations are authorised and logged; every alarm is checked at once.

How to answer
  • Explain the panel: which zones cover which spaces, how a fire alarm differs from a fault, and where repeaters are (bridge, ECR, fire control station)
  • Explain any delay before the general alarm (e.g. on manned bridge acknowledgement) and that it follows approved settings
  • Describe the test routine: detectors tested with test gas, smoke or heat in rotation, manual call points tested, all recorded in the PMS
  • Describe actions on an alarm: acknowledge, send someone to check the location, inform the Master, fire party on standby, reset only when cause found
  • Explain how isolations are authorised, logged with time and reason, and restored when work ends
Have ready
  • Fire detection main panel and repeaters
  • Detector and call point test records
  • Detector isolation log / hot work permits
  • Detector location plan / zone list
  • PMS maintenance history and maker's manual
  • Test kits (test gas, heat tester)

5.2.4 Machinery space fixed carbon dioxide fire extinguishing system Rotational 1

Where machinery spaces are protected by fixed CO2, do the Master and officers know where the system is, its purpose and how to release it, and is it ready to use at once, with release steps and operating guidance posted at each control position?

In one lineHead count, close openings, stop fans and fuel, open cabinet for alarm, release with both controls; CO2 room clear and serviced.

How to answer
  • Walk through the release: Master's decision, head count of the engine room, stop ventilation and close all openings and dampers, stop fuel pumps (quick-closing valves), open release cabinet (alarm sounds), operate the two separate controls
  • Explain that the space is not reopened until cooled and confirmed safe, and re-entry only with BA
  • State the precautions for entering the CO2 room: check ventilation is running, inform the bridge, never alone
  • Explain maintenance: periodic contents checks by weight or liquid level, inspection of pipework, hoses and actuators, annual service by approved firm
  • Explain where the release controls are and who holds the keys
Have ready
  • CO2 room, cylinders and control heads
  • Release cabinets with posted instructions
  • Shore service certificate/report
  • Onboard inspection records in the PMS
  • Fire control plan
  • Engine room head-count arrangements

5.2.5 Machinery space fixed high-expansion foam fire extinguishing system Rotational 1

Where a high-expansion foam system protects the machinery space, are the Master and officers familiar with its location, purpose and operation, and is it in good order, ready for immediate use, with operating instructions clearly posted at the control positions?

In one lineI know the foam tank, control station and spaces covered; release after head count and closing openings; foam analysed in date.

How to answer
  • Explain where the foam concentrate tank, pump and control station are and which spaces are covered
  • Walk through operation: head count, stop ventilation, close openings, start system from the control station
  • Explain maintenance: tank level checks, valve and generator inspections, nozzle/screen checks per PMS
  • State when the foam concentrate was last sampled and the result
  • Explain why high-expansion foam needs air supply to the generators and the effect on visibility in the space
Have ready
  • Foam system control station and posted instructions
  • Foam concentrate tank and level gauge
  • Foam analysis certificate
  • PMS maintenance records
  • System diagram

5.2.6 Machinery space fixed pressure water-spraying fire extinguishing system Rotational 1

Where the machinery space has a fixed pressure water-spraying system, do the Master and officers know where it is, what it is for and how it works, and is it ready for immediate use with clear operating instructions at the control positions?

In one lineI know the supply tank, the sections and how to start the pump and open a section; it is tested and instructions are posted.

How to answer
  • Name the fresh water tank that feeds the system and show the level is maintained
  • Explain which sections cover which areas and how each section valve is opened
  • Walk through activation: start the pump locally/remotely, open the section valve, confirm pressure
  • Explain maintenance: regular pump test, section valve operation, nozzle and strainer checks
  • Describe the backup supply (e.g. sea water) when the fresh water tank empties
Have ready
  • System pump unit and section valves
  • Posted operating instructions
  • Fresh water supply tank and level indication
  • PMS test and maintenance records
  • Section/coverage diagram

5.2.7 Fire pumps, fire main, fire main isolating valves and fire hydrants Rotational 1

Are the Master and officers familiar with where the fire pumps, fire main, isolating valves and hydrants are, what they do and how to operate them, and is the whole system in good condition and ready for immediate use?

In one lineFire pumps start locally and remotely; isolating valves and drains are known and marked; hydrants and main are in good order.

How to answer
  • Explain how the main fire pumps are started locally and remotely and how pressure is confirmed
  • Show the isolating valves and explain why the deck main can be isolated from the machinery space
  • Show where the deck fire main drains are and explain draining in cold weather
  • Explain the inspection/test routine for hydrants and valves
  • Describe how damaged sections of fire main are isolated
Have ready
  • Fire pumps and remote start positions
  • Isolating valves on fire main
  • Fire main drains
  • Hydrants with hoses
  • PMS records
  • Fire main pressure test records

5.2.8 Galley fixed and portable fire extinguishing systems & fire prevention Rotational 1

Do the Master, officers and galley staff know where the galley's fixed and portable fire extinguishing equipment is, what it is for and how to use it, is that equipment ready for use, and are ranges, exhaust ducts, filters and cowls kept clear of grease and combustible material?

In one lineKill the power and fans, smother with blanket or release the hood system; never water on oil; filters and ducts kept grease-free.

How to answer
  • Explain the galley fixed system: what it covers (hood, duct, fryer), where the manual release is and what it does
  • Explain how to use the fire blanket and why water must never be used on a burning oil pan
  • Show how to stop galley exhaust and supply fans and close the duct fire damper
  • Explain the cleaning routine for filters, hoods and ducts and how it is recorded
  • Describe isolating power to ranges and fryers in an emergency
Have ready
  • Galley fixed fire extinguishing system and release
  • Fire blanket and portable extinguishers
  • Galley ventilation stops and duct damper
  • Filter/hood/duct cleaning records
  • Range emergency stop / power isolation
  • Fryer thermostat and high-temperature cut-out

5.2.9 Water-spray system on deck Rotational 1

On gas carriers, are the Master and officers familiar with where the deck water-spray system is, what it does (cooling, fire prevention, crew protection) and how it works, and is it in good order with regular inspection, testing and maintenance?

In one lineThe water spray cools and protects domes, manifolds and accommodation front; I know the valves and drains; it's tested and nozzles cleared.

How to answer
  • Explain the system's purpose: cooling of tanks and structures, protecting escape routes and crew, preventing ignition
  • Show the isolating/section valves and explain which part of the deck each one serves
  • Show the drains and explain draining after use and in sub-zero conditions
  • Describe the test routine and how blocked nozzles are found and cleared
  • Explain how the system is started from remote position(s) and pump arrangements
Have ready
  • Water-spray system diagram
  • Section/isolating valves and drains
  • Test records with nozzle condition
  • Remote start positions
  • PMS maintenance records

5.2.10 Cargo handling equipment space(s) fixed fire extinguishing system Rotational 1

On gas carriers, do the Master and officers know where the fixed fire extinguishing system for enclosed cargo machinery spaces (compressor and motor rooms) is, its purpose and operation, and is it ready for use with release procedure and instructions displayed at the control stations?

In one lineCO2 protects the compressor/motor rooms; stop machinery, head count, close up, release from the posted station; serviced and checked.

How to answer
  • Explain which spaces are protected and where the release controls are
  • Walk through the release: stop cargo machinery, head count, close ventilation and doors, open cabinet, release
  • Explain safety precautions before entering the CO2 storage room: ventilate, inform, not alone
  • Explain servicing and onboard checks
  • Explain re-entry only after ventilation and atmosphere testing with BA
Have ready
  • Release station and posted instructions
  • CO2 storage room/cylinders
  • Service reports
  • PMS records
  • Fire control plan

5.2.11 Fixed dry chemical powder fire extinguishing system Rotational 2

On gas carriers with a fixed dry chemical powder system, do the Master and officers know where it is, what it is for and how it operates, and is it ready for immediate use with clear operating instructions posted at each control position?

In one linePressurise with nitrogen, open the outlet, aim at the base of the fire; purge lines after use; propellant and powder checked.

How to answer
  • Explain where the powder units, monitors and hose reels are and which areas they cover
  • Walk through operation: open the nitrogen to pressurise the container, open the outlet, use monitor or hose gun
  • Explain why the lines are purged with nitrogen after use
  • Describe the maintenance: pressure checks of propellant, powder condition check (no caking), nozzle checks
  • Explain dry powder is used for gas fires and water spray is used for cooling, not for extinguishing
Have ready
  • DCP units and hose reels
  • Posted operating instructions
  • Nitrogen cylinder pressure records
  • Powder sample/condition checks
  • PMS records
  • Fire control plan

5.2.12 Paint locker fixed fire-extinguishing system Rotational 2

Do the Master and officers know the fixed extinguishing system protecting the paint locker and any other store for flammable liquids, and is it in good order and ready for immediate use?

In one lineI know the system, the outside release and how to use it; locker is tidy, ventilated and flammables stored safely.

How to answer
  • Explain the type of system and where the release is
  • Walk through release: ensure nobody inside, close door and ventilation, operate release
  • Explain precautions: close containers, no smoking, no non-Ex lighting
  • Explain how the system is checked and maintained
  • Explain where other flammables (e.g. chemicals, thinners) are stored
Have ready
  • Paint locker and its fixed system
  • Release point and instructions
  • PMS records
  • Inventory of flammables
  • Ventilation arrangements

5.2.13 Machinery space fixed water-based or equivalent local application fire-fighting system Rotational 2

Where the machinery space has a fixed local application fire-fighting system (water mist or an equivalent), do the Master and officers know where it is, its purpose and operation, and is it ready for immediate use with clear instructions at the control positions?

In one lineMist covers engine fuel areas, purifiers and boiler; automatic during UMS, manual when manned as configured; tested regularly.

How to answer
  • Explain which high-risk areas are covered and how sections are arranged
  • Explain the release modes: automatic on detection, manual from the panel and local valves; explain how it is set during UMS and when the engine room is manned
  • Walk through manual activation and shutting off
  • Describe the testing routine and record
  • Explain why water mist is safe for persons but equipment needs isolating afterwards
Have ready
  • Local application panel
  • Section valves and nozzles
  • Posted instructions
  • Test records
  • Supply pump and tank

5.2.14 Cargo, ballast and stripping pump temperature sensing devices Rotational 2

On oil and chemical tankers with pumps in a pump room, do the Master and officers understand why temperature sensors are fitted on cargo, ballast and stripping pumps, and can they show that alarm points have been correctly set and tested in line with company and maker requirements?

In one lineSensors warn of hot bearings, glands and casings; set per maker; tested and recorded; on alarm stop the pump and investigate.

How to answer
  • Explain that SOLAS requires temperature sensors on pump bulkhead shaft glands, bearings and casings in cargo pump rooms to prevent ignition from overheating
  • State the alarm set points and where they are taken from
  • Explain how the sensors are tested and recorded
  • Describe actions on high-temperature alarm: stop the pump, investigate, do not restart until the cause is found
  • Explain the display location and the alarm acknowledgment
Have ready
  • Temperature alarm panel in the CCR
  • Set point list from maker
  • Test records
  • PMS entries for sensor tests
  • Pump room monitoring records

5.2.15 Deck foam system, including portable applicators Rotational 2

On oil and chemical tankers, do the Master, officers and ratings understand what the deck foam system and its portable applicators are for and how they are operated, and is the system ready for immediate use with instructions posted at the control station?

In one lineStart the fire pump, open foam valve, use monitors/applicators from upwind, apply gently; foam analysed in date.

How to answer
  • Explain starting the foam system: start fire pump, open foam concentrate valve, check proportioner, open monitor or hydrant
  • Show how to use a portable applicator and monitor, aiming foam gently onto a surface (off a structure) rather than plunging
  • Explain fighting a spill fire: approach from upwind, lay foam blanket progressively
  • Explain fighting a ruptured tank fire: monitors from a distance, cooling adjacent tanks
  • State when the foam was last analysed
Have ready
  • Foam room and concentrate tank
  • Monitors and portable applicators
  • Posted instructions
  • Foam analysis report
  • PMS records

5.2.16 Fire doors Rotational 2

Do the Master, officers and crew know where the ship's fire doors are, why they are fitted, how they are tested and how they work?

In one lineFire doors keep fire zones intact; they close and latch on their own, are tested, and are never wedged open.

How to answer
  • Explain that fire doors keep the fire zones and stairway enclosures intact to stop the spread of fire and smoke
  • Point out fire doors on the fire control plan and at the actual locations
  • Explain the test: release the door, check it closes and latches without help, check seals, closers and any remote release
  • State that doors are never wedged open and any defective closer is reported and repaired
  • Explain how the remote release and indication panel work where fitted
Have ready
  • Fire control plan with fire doors marked
  • Fire door test records in the PMS
  • Door closers, seals and hold-back magnets
  • Remote release panel
  • Defect reports for doors repaired

5.3.1 Firefighter’s outfits including self-contained breathing apparatus (SCBA) Rotational 1

Do the Master, officers and ratings know where the firefighter's outfits and self-contained breathing apparatus are kept and how to use them, and is the equipment well maintained and ready for immediate use as the company requires?

In one lineI can don and check an SCBA, know its pressure and endurance, recharge cylinders safely; sets are checked monthly and serviced annually.

How to answer
  • Demonstrate donning: check cylinder pressure, positive pressure and face seal check, low-pressure warning test
  • State the working pressure of the cylinders on board and the approximate duration, remembering effort and stress reduce it
  • Explain cylinder changing and recharging, and that the compressor is run with clean air intake away from exhausts
  • Explain hygiene: face masks cleaned and disinfected after use
  • Describe maintenance: monthly checks, annual service by approved firm, hydrostatic testing of cylinders at the required interval, air quality test
Have ready
  • Firefighter's outfits and fire lockers
  • SCBA sets and spare cylinders
  • Monthly inspection records
  • Annual service certificates and cylinder test dates
  • Breathing air compressor and air quality test results
  • Fire-fighting team two-way radios

5.3.2 Fire hoses, nozzles and international shore connection Rotational 2

Do the Master, officers and crew know where the fire hoses and nozzles and the international shore connection are kept, what they are for and how they are used, and is this equipment in good condition and ready for use?

In one lineHoses and dual-purpose nozzles at every hydrant; ISC complete with bolts and gasket; hoses tested regularly.

How to answer
  • Explain the hose and nozzle arrangement and show a hose box
  • Explain switching between jet and spray and when each is used
  • Show the international shore connection, its location and contents
  • Explain when the ISC is used: connecting to a shore fire main or another ship
  • Describe hose inspection/pressure testing routine
Have ready
  • Hose boxes at hydrants
  • Dual-purpose jet/spray nozzles
  • International shore connection and its fittings
  • Hose test records
  • PMS entries for hoses and the shore connection

5.3.3 Portable fire extinguishers Rotational 2

Do the Master, officers and ratings know where the portable fire extinguishers are, which fires each is for and how to use them, and are the extinguishers in good order, readily accessible and clearly marked with operating instructions?

In one linePin, aim at the base, squeeze, sweep; right type for each risk; checked onboard, serviced annually, spares carried.

How to answer
  • Explain the types on board and the fire class each one is for (e.g. CO2 for electrical equipment, foam for oil fires)
  • Describe use: remove pin, approach from upwind/with escape behind you, aim at the base, short bursts, sweep
  • Explain the hazard of CO2 in a small space and the cold discharge horn
  • Describe the inspection routine: regular visual checks onboard, annual service by competent person, periodic pressure testing of shells
  • Show where spare charges are stored and how a used extinguisher is replaced and reported
Have ready
  • Extinguishers in their brackets at plan locations
  • Service and inspection labels
  • Spare charges / spare extinguishers
  • Inspection records in the PMS
  • Fire control plan

5.3.4 Emergency Escape Breathing Devices (EEBDs) Rotational 2

Do the Master, officers and ratings know where the Emergency Escape Breathing Devices are kept and what they are for, and are the EEBDs in good condition, sensibly positioned and ready for immediate use?

In one lineEEBDs are for escape only, about ten minutes of air; I know where they are on my escape route; they're checked regularly.

How to answer
  • Name the EEBD locations near your workplace and cabin, especially in the engine room escape routes
  • State that EEBDs are only for escaping from smoke or a dangerous atmosphere and must never be used for firefighting or to enter an enclosed space
  • Describe donning: open the case, pull the hood over the head, check air flowing, leave by the nearest escape route
  • Explain the inspection: check gauge, seal and condition at the company interval, servicing per maker
  • Mention the training EEBD used for familiarisation
Have ready
  • EEBDs and their location markings
  • Spare EEBDs
  • Fire control plan / safety plan
  • Inspection and service records
  • Training EEBD

5.3.5 Wheeled (mobile) fire extinguishers Rotational 2

Do the Master, officers and engine ratings understand the purpose and operation of the wheeled (mobile) fire extinguishers, and is this equipment in good order, ready for immediate use and clearly marked with operating instructions?

In one lineWheel it in, run the hose out fully, activate and hit the base of the fire; units placed by high-risk areas and serviced.

How to answer
  • Point out the wheeled extinguisher locations in the engine room and the fire risks they cover
  • Walk through use: release from its securing, wheel into position, run out the hose without kinks, activate, aim at the base of the fire
  • Explain the agent type and size and which fires it is suitable for
  • Describe maintenance: onboard checks, annual servicing, periodic shell pressure test, recharge after use
  • Explain that the unit is reported and replaced or recharged immediately after any discharge
Have ready
  • Wheeled extinguishers and their positions
  • Operating instructions on the unit
  • Service labels and certificates
  • PMS inspection records
  • Fire control plan

5.4.1 Davit-launched lifeboats, release mechanisms and launching appliances Core

Where davit-launched lifeboats are fitted, do the Master and officers know how the boats, their release gear and launching appliances work, and are they in good order with records proving the required inspections and tests?

In one lineWeekly and monthly checks, annual and five-yearly service done; I can explain hook release, reset checks and launching safely.

How to answer
  • Walk through the monthly checklist: engine run, hook release mechanism and indicators, falls, davit and winch, brake, boat equipment and stores
  • Explain how the hooks are released on and off load, the hydrostatic interlock, and how to confirm the hooks are fully reset (indicator/visual check) before hoisting
  • Explain the use of fall preventer devices where the company requires them and when they are removed
  • State the dates of the last annual examination and five-yearly service, and the falls end-for-end and renewal dates
  • Explain launching from inside the boat and from the deck, and recovery precautions
Have ready
  • Weekly/monthly LSA inspection records
  • Annual and five-yearly service reports for release gear, davits and winches
  • Falls renewal/end-for-end records
  • Operating instructions at the boat and in the boat
  • Training manual and LSA maintenance manual
  • Lifeboat equipment inventory

5.4.2 Free-fall lifeboat, its release systems and its launching appliance Core

Where a free-fall lifeboat is fitted, do the Master and officers know how the boat, its release gear and its launching arrangement work, and is the equipment in good condition with records showing inspection and testing in line with company procedures?

In one lineAll strapped, hatch closed, engine running, then hydraulic release; simulated launch only with restraints checked; serviced and inspected.

How to answer
  • Explain the release: all seated and strapped, hatch closed, engine started, operate hand pump to release
  • Describe the simulated launch arrangement and the checks to make sure the restraining device is correctly fitted before a drill
  • Explain the engine and emergency steering operation
  • Walk through the monthly checks and their record
  • State when the boat was last free-fall launched or simulated
Have ready
  • Weekly/monthly LSA inspection records
  • Annual service report
  • Operating instructions
  • Simulated launch device
  • Drill records

5.4.3 Dedicated rescue boat and launching appliance Core

Do the Master and officers know how to operate the dedicated rescue boat and its launching appliance, and are they in good order with records showing the required inspections and tests?

In one lineI can start the rescue boat, engage drive, slew and lower without main power; boat launched regularly and serviced.

How to answer
  • Demonstrate the starting procedure and engagement of the drive/outboard
  • Explain how to slew and lower the boat using stored power or manual means
  • Describe routine checks: tubes, hull, engine, fuel, painter, release hook, equipment list
  • State the dates of last launch and service
  • Explain recovery precautions and the risk of hook-on in a seaway
Have ready
  • Rescue boat and davit
  • Weekly/monthly LSA inspection records
  • Annual service reports
  • Launching records
  • Operating instructions
  • Equipment inventory

5.4.4 Rocket parachute flares and line throwing appliances Rotational 2

Do the Master and officers know where the rocket parachute flares and the line-throwing apparatus are kept, what they are for and how to use them, and are these items in good order with records showing the required inspections?

In one lineTwelve flares on the bridge and a complete line-thrower, all in date and inspected; I can explain how to fire both safely.

How to answer
  • Show where the flares are kept on the bridge and state the quantity and expiry dates
  • Explain firing a flare: read instructions, hold firmly at arm's length pointing up and slightly downwind, keep clear of the end, never look into it
  • Explain when they are used (distress) and that they are not for training firing
  • Explain the line-throwing appliance: location, how to load and fire, aiming over the target, keeping the line clear
  • Explain inspection and what happens to expired pyrotechnics (landed to an authorised shore facility)
Have ready
  • Rocket parachute flares and their stowage
  • Line-throwing appliance
  • Pyrotechnics inventory with expiry dates
  • Monthly LSA inspection records
  • Receipts for disposal of expired pyrotechnics

5.4.5 Liferafts, hydrostatic releases and liferaft launching appliances Rotational 2

Are the Master and officers familiar with how the liferafts, their hydrostatic release units and any liferaft launching appliances work, and are these in good order with records showing service, inspection and testing as required?

In one lineRaft and HRU in date, painter via the weak link; float-free and manual launch both understood.

How to answer
  • Explain float-free: the HRU releases the raft at depth, the raft floats up, the painter pulls to inflate and the weak link then breaks
  • Explain manual launch: check water below clear, release the lashing, throw overboard, pull the painter to inflate, board
  • Show service labels and HRU dates and state when the next service is due
  • Explain davit-launched raft operation where fitted: attach hook, inflate alongside, board, lower, release
  • Explain weekly/monthly inspections of lashings, HRU and stowage
Have ready
  • Liferafts and their service labels
  • Hydrostatic release units with expiry dates
  • Liferaft service certificates
  • Davit-launched liferaft and service records
  • Monthly LSA inspection records
  • Embarkation ladders near liferaft stations

5.4.6 Lifebuoys, and associated lights, smoke floats and lifelines Rotational 2

Are the lifebuoys with their lights, smoke signals and buoyant lines in good condition, properly marked and correctly positioned around the ship?

In one lineLifebuoys as per safety plan, free to throw, marked; lights, smoke signals and lines in date and checked.

How to answer
  • Explain the arrangement: where the bridge-wing MOB lifebuoys are and how they are released
  • Show the lifebuoys with lines and lights and how they are secured (not lashed)
  • Explain inspection: check lights, smoke signals' expiry, lines, markings
  • State that on tankers the self-igniting lifebuoy lights must be the electric battery type, not pyrotechnic
  • Explain replacement of expired items
Have ready
  • Lifebuoys around the ship
  • Safety plan showing positions
  • Expiry records of lights and smoke signals
  • LSA inspection records
  • Bridge-wing MOB lifebuoys

5.4.7 Immersion suits Rotational 2

Do the Master, officers and ratings know the immersion suits carried on board, and are the suits in good condition, easy to reach and their stowage positions clearly marked?

In one lineMy suit is at a marked location, the right size, checked, and I can put it on within two minutes.

How to answer
  • Explain where your suit is stored and its size
  • Demonstrate donning: sit down, legs first, arms, hood, zip, within about two minutes
  • Explain inspection: zip lubricated, seams and seals intact, light working
  • Explain periodic air-pressure test interval as required by company/flag
  • Explain checking suits after use and drying
Have ready
  • Immersion suits and their marked locations
  • Inspection records
  • Pressure test records
  • Muster list
  • Spare suits

5.4.8 Lifejackets and personal flotation devices (PFDs) Rotational 2

Do the Master, officers and ratings know the lifejackets and personal flotation devices carried on board, and are these items in good condition and looked after properly?

In one lineLifejacket in my cabin and at stations; working PFDs worn as the company requires; all inspected and inflatables serviced.

How to answer
  • Explain where your lifejacket is and how to don it quickly
  • Explain the company's requirement for working lifejackets/PFDs and when they are worn
  • Explain inspection: light, whistle, strap, fastening
  • Explain servicing of inflatable PFDs: cylinder and auto-inflator checks and annual service
  • Show spare lifejackets at watch stations
Have ready
  • Lifejackets in cabins and at stations
  • Working lifejackets / PFDs
  • Inspection records
  • Service records for inflatables
  • Muster list

5.4.9 Emergency lighting Rotational 2

Do the Master and officers know the company's procedures for routinely testing and maintaining the emergency lighting, is there evidence the tests have been done, and is the system working properly?

In one lineEmergency lighting runs from the emergency switchboard with battery back-up; it's tested to the PMS and every failed light is fixed.

How to answer
  • Explain how emergency lighting is supplied: emergency switchboard fed by the emergency generator, with batteries as transitional source
  • Show where the emergency lighting switches/circuit breakers are on the emergency switchboard and any local test buttons
  • Describe the test routine in the PMS and what is checked (all fittings lit, battery changeover, duration)
  • Explain how battery banks are maintained (voltage, electrolyte, terminals, ventilation)
  • Explain how a failed light is reported and the repair recorded
Have ready
  • Emergency switchboard and lighting circuits
  • Emergency lighting test records in the PMS
  • Emergency generator and battery test records
  • Battery room / battery maintenance log
  • Emergency lights at muster and embarkation stations

5.5.1 Enclosed space entry procedures Core

Do the Master, officers and ratings know the company's enclosed space entry procedure, and can the ship show that every entry has been made fully in line with it?

In one lineNo permit, no entry: ventilate, test (O2 21%, HC ≤1% LFL, toxics <50% OEL), rescue gear ready, attendant never leaves.

How to answer
  • Explain the permit steps: risk assessment, isolation, ventilation, atmosphere test, rescue equipment ready, permit authorised by the responsible officer, briefing
  • State the acceptable atmosphere: oxygen 21% by volume, flammable gas not more than 1% LFL, toxic gases below 50% of their exposure limit (ISGOTT values; follow company limits if stricter)
  • As attendant: stay at the entrance, keep count of entrants, keep contact, never enter, raise alarm
  • As entrant: carry a personal multi-gas meter, leave immediately if the alarm sounds or conditions change
  • Show completed permits and readings for recent entries
Have ready
  • Enclosed space entry permits and log
  • Gas meter calibration and bump test records
  • Rescue equipment at entrance
  • Enclosed space list and warning signs
  • Risk assessment
  • Communication equipment

5.5.2 Hot work procedure Rotational 1

Do the Master, officers and any ratings directly involved know the company hot work procedure, and is there evidence that hot work has been carried out in line with it?

In one lineOutside the workshop: permit, RA, gas test, isolations, fire watch, approval; stop if conditions change.

How to answer
  • Explain that hot work in the designated workshop follows workshop rules, and outside it needs a permit, risk assessment and approvals as the SMS requires
  • Describe the precautions: area and adjacent spaces cleaned, gas-freed and tested, pipelines isolated, combustibles removed, fire watch with extinguisher/hose
  • Explain that hot work stops if gas readings rise or cargo/bunker operations start
  • Describe your role (e.g. fire watch) and how long the area is monitored after work ends
  • Explain checks of welding equipment and gas bottles
Have ready
  • Hot work permits
  • Risk assessments
  • Gas test records
  • Welding equipment and flashback arrestors
  • Fire-fighting equipment at site
  • Company approval emails

5.5.3 Working at height Rotational 2

Do the Master, officers and ratings know the company rules for work aloft, and can the ship show that controls such as work permits or written risk assessments are applied every time someone works at height?

In one linePermit and RA, harness clipped to a strong point, helmet, area below cleared, standby person; stop if weather or motion worsens.

How to answer
  • Explain when a permit is needed (company's height threshold, typically above 2 m or where a fall is possible) and who authorises it
  • Describe the PPE: full body harness, lanyard clipped to a suitable strong point, helmet with chin strap, non-slip footwear
  • Explain precautions: radar/whistle/antenna isolations when working on masts, area below barricaded, tools on lanyards, standby person
  • Explain that work stops in high wind, rain or rolling and that contractors follow the ship's permit and supervision
  • Describe the pre-use check of the harness (webbing, stitching, buckles, labels) and removal of damaged items
Have ready
  • Work at height permits and risk assessments
  • Harnesses, lanyards and inertia reels
  • Inspection register for fall-arrest equipment
  • Toolbox talk / work planning records
  • Contractor briefing records

5.5.4 Working over the side Rotational 2

Do the Master, officers and ratings know the company procedures for work over the ship's side, and is there evidence that controls such as standard procedures, permits or documented risk assessments are used every time this work is done?

In one linePermit, lifejacket plus harness and independent lifeline, standby person with lifebuoy, ship stopped and weather suitable.

How to answer
  • Explain the permit/RA process and who approves it
  • Describe PPE: working lifejacket, harness with lifeline secured independently of the stage, helmet
  • Explain the safety set-up: standby person on deck, lifebuoy with line at hand, communication with bridge/duty officer
  • Explain conditions where work is not done: underway, propeller turning, bad weather, during cargo transfer if company prohibits
  • Explain stage/bosun's chair inspection before use
Have ready
  • Over-side work permits and RAs
  • Working lifejackets and harnesses
  • Lifebuoy with line
  • Stage/bosun's chair inspection records
  • Toolbox meeting records

5.5.5 Working on electrical equipment and systems Rotational 2

Do the Master and officers know the company procedures for work on electrical equipment and systems, and is there evidence that controls such as permits and/or documented risk assessments are always used for this work?

In one linePermit, isolate, lock and tag, prove dead; live work only when unavoidable and approved; HV and hazardous areas under special permit.

How to answer
  • Explain the safe procedure: permit, isolate at the source, lock and tag, test for dead with a proven tester, earth where required
  • Explain that live work is only done when unavoidable, approved by the Chief Engineer/Master, with insulated tools, mat, second person
  • Explain the high-voltage procedure: authorised person, switching programme, earthing, permit to work, sanction to test
  • Explain hazardous area work: only certified (Ex) equipment, gas test, permit, no opening of Ex enclosures while live
  • Show completed isolation records
Have ready
  • Electrical work permits
  • LOTO kit and register
  • HV switching procedures
  • Insulated tools, mats and test meters
  • Hazardous area equipment register
  • Risk assessments

5.5.6 Control of hazardous energy Rotational 2

Do the Master and officers know the company procedures for controlling hazardous energy, and can they show, through documented risk assessments or permits, that energy sources are routinely identified and isolated before anyone works on machinery, systems or spaces where they may be present?

In one lineIdentify every energy source, isolate, lock and tag, prove zero energy, record it, and remove only when authorised.

How to answer
  • Explain the process: identify energy sources, plan isolations, apply locks and tags, verify zero energy, start work
  • Give examples: depressurising a hydraulic line, draining a pipe, blocking a suspended load
  • Show the isolation register and how it links to the permit
  • Explain how isolations are removed and who authorises
  • Explain shift handover of isolations
Have ready
  • Isolation register / lock-out log
  • Lock-out/tag-out kit with personal locks
  • Permits to work and risk assessments listing isolations
  • Isolation certificates for complex systems
  • Company hazardous energy control procedure

5.6.1 Portable and personal gas measurement instruments Core

Do the Master and officers understand the purpose, use, testing, maintenance and calibration of the ship's portable and personal gas detectors, and is there enough equipment on board, in good order, regularly tested and periodically calibrated?

In one lineRight meter for each gas, bump test before use, span calibration with in-date gas, shore service on time; catalytic LEL not in inert atmosphere.

How to answer
  • Explain the instruments on board and what each measures: catalytic or IR for flammables, electrochemical for O2 and toxics, IR for hydrocarbon % volume in inerted tanks
  • Explain why a catalytic LEL sensor should not be used in an inerted tank and which meter is used instead
  • Describe the bump test before each use and the span calibration with calibration gas, and show the gas cylinders' expiry
  • State that personal multi-gas meters are worn by everyone entering an enclosed space
  • Show the spares carried and the shore calibration certificates
Have ready
  • Portable and personal gas detectors
  • Calibration gas cylinders with expiry dates
  • Bump test and calibration records
  • Shore calibration certificates
  • Spare sensors, filters and sampling lines
  • Toxic gas detector tubes and their expiry dates

5.6.2 Testing the atmosphere in double-hull and double bottom spaces for flammable gas Rotational 1

On oil and chemical tankers, do the Master and deck officers know the company procedures for checking the double-hull and double-bottom tanks for flammable gas, and do records confirm the readings were taken with the fixed or portable equipment provided?

In one lineMonitor ballast and void spaces at the company interval with fixed or portable equipment, purge lines, record and act on any rise.

How to answer
  • Explain the monitoring frequency and method: fixed system, or portable meter via sampling points at upper and lower levels
  • Explain how sampling lines are purged before taking a reading
  • Describe the action on a reading above the company threshold: report, investigate leak, ventilate, consider cargo transfer
  • Show the monitoring records
  • Explain calibration of the fixed system and portable meters
Have ready
  • Double-hull gas monitoring records
  • Fixed gas detection system
  • Sampling points and lines
  • Portable meters and calibration records
  • Company double-hull monitoring procedure

5.6.3 Fixed gas detection systems required by the IGC Code Rotational 1

On gas carriers, do the Master and officers know where the IGC Code fixed gas detection equipment is, what it is for and how it works, and is it in good order, maintained and calibrated?

In one lineI know the monitored spaces, panel and set points; the system is calibrated with the right span gas and no point is left isolated.

How to answer
  • Explain which spaces are monitored, where the main panel is and where alarms repeat (bridge, CCR)
  • Explain how the system samples each point and how long a full cycle takes
  • State the alarm set points and the action on alarm: identify the space, ventilate, investigate the leak, stop cargo machinery if needed
  • Describe calibration: zero and span with the correct span gas for the cargo, at the interval in the PMS/maker's manual
  • Explain how blocked lines are found (flow indicators) and how isolations are recorded
Have ready
  • Fixed gas detection panel and repeaters
  • List of sampling points and spaces
  • Calibration records and span gas cylinders
  • Maker's manual and PMS records
  • Alarm/isolation log

5.6.4 Fixed gas detection system required by the IGF Code Rotational 1

On ships using gas as fuel under the IGF Code, do the Master and officers know where the fixed gas detection system is, its purpose and operation, and is it in good order, maintained and calibrated in line with company procedures and the maker's instructions?

In one lineDetectors cover all gas fuel spaces and ducts; I know the alarm and shutdown points; tested, calibrated and bypasses controlled.

How to answer
  • Explain the spaces monitored and where the panels and alarms are
  • State the alarm and shutdown set points for your ship and what happens automatically at each (e.g. master gas valve closes, ventilation changes)
  • Describe the routine tests of shutdown functions and how they are recorded
  • Describe zero/span calibration routine and who does the shore service
  • Explain that bypasses need authorisation, are logged and are removed as soon as possible
Have ready
  • Fuel-handling manual
  • Gas detection and gas safety system panels
  • Calibration and span gas records
  • Shutdown test records
  • Bypass/inhibit log
  • PMS records

5.6.5 Cargo pump room fixed gas detection system Rotational 2

On oil and chemical tankers with cargo pump rooms, do the Master and officers know how to operate and maintain the pump room's fixed gas detection, and is it fully working with calibrated sensors and alarm points set per company and maker requirements?

In one linePump room gas detection runs continuously with alarms in CCR and bridge; calibrated, set correctly and checked before every entry.

How to answer
  • Explain the system: sampling points, analyser location, alarm repeaters
  • State the alarm set point and the action on alarm: no entry, ventilate, investigate
  • Explain the calibration routine and show records
  • Explain that readings are checked before pump room entry and that portable meters are also used
  • Explain what is done if the system fails: portable monitoring and entry restrictions until it is repaired
Have ready
  • Pump room gas detection panel
  • Calibration records
  • Span gas cylinders in date
  • Pump room entry log
  • PMS records for the analyser

5.6.6 Oxygen sensors in inert gas system spaces Rotational 2

On oil and chemical tankers, do the Master and officers know how to operate and maintain the oxygen sensors and alarms in the compartment(s) housing the inert gas plant, and is that equipment fully working with sensors calibrated and alarm points correctly set?

In one lineO2 sensors in the IG space warn of leaks; alarm set and tested; on alarm evacuate and do not enter without BA.

How to answer
  • Explain where the sensors are and why: leaking inert gas or nitrogen can displace oxygen without warning
  • State the alarm set point and where the alarm sounds (in the space, at the entrance, CCR/bridge)
  • Describe calibration and test routine, using clean fresh air (20.9% O2) as the reference point and nitrogen or a certified test gas for the low point, as the maker specifies
  • Describe actions on alarm: do not enter, evacuate, ventilate, investigate the leak, re-enter only after testing or with BA
  • Show the calibration and alarm test records
Have ready
  • Oxygen sensors and alarm panel
  • Calibration records and calibration gas
  • Alarm functional test records
  • Maker's manual for the sensors
  • PMS entries for the O2 monitoring system

5.7.1 Incident investigation reports for defined incidents Core

Have all incidents on board been reported and investigated as the company procedure requires, and for every incident at or above the company's defined severity level, is there an investigation report or a lessons-learned summary available?

In one lineEvery incident reported; those above the threshold investigated with root causes and actions; lessons shared and actions closed.

How to answer
  • Explain the company's incident classification and which level triggers a full investigation
  • Walk the inspector through a recent investigation: timeline, root causes, actions, close-out
  • Explain how lessons learned are shared with crew (safety meetings, notices) and fleet-wide circulars received
  • Show that all actions are closed or have a target date
  • Explain how ISM Code element 9 reporting is applied on board
Have ready
  • Incident register
  • Investigation reports
  • Lessons-learned bulletins
  • Corrective action tracker
  • Safety meeting minutes where lessons were discussed

5.7.2 Incident and near-miss reporting procedure Rotational 1

Do the Master, officers and ratings know the company procedure for reporting incidents and near-misses, and can the ship show that these were investigated and closed out as that procedure requires?

In one lineReport it to the supervisor and in the company system; it's investigated, tracked to closure and the lesson shared; no blame for reporting.

How to answer
  • Explain the reporting route: tell the OOW or supervisor, complete the near-miss form or system entry, Master reviews and sends to the office
  • Give a real example of a near-miss you reported or know of, its cause and what changed afterwards
  • Explain how reports are tracked (register or system status) until actions are complete and verified
  • Describe how outcomes are shared: safety meetings, toolbox talks, notice board
  • State that reporting is encouraged and nobody is punished for honest reporting
Have ready
  • Near-miss and incident reports
  • Near-miss register or system tracking page
  • Safety committee minutes discussing reports
  • Evidence of corrective actions completed
  • Company feedback or fleet circulars

5.7.3 Shipboard safety meetings Rotational 1

Do the Master, officers and ratings know how the company requires shipboard safety meetings to be held and recorded, and is there evidence that safety concerns raised in those meetings were acknowledged and dealt with by the office?

In one lineSafety meetings held on schedule; minutes sent ashore; office replies on file; every concern tracked to closure.

How to answer
  • State the date of the last safety meeting and one item that was discussed
  • Explain how you raise concerns: directly in the meeting, through your department representative, or beforehand to the safety officer
  • Show the minutes and the office's written response to the issues raised
  • Explain how items needing shore help (spares, procedures) are followed up and closed
  • Explain how crew on watch during the meeting are briefed afterwards
Have ready
  • Safety committee meeting minutes
  • Office feedback/acknowledgement
  • Action tracking list
  • Attendance records
  • Safety notice board

5.7.4 Work planning procedure Rotational 1

Do the Master, officers and ratings know the company's work planning procedures, and are there records showing that work planning meetings on board have been held and documented as those procedures require?

In one lineDaily work planning meetings cover tasks, hazards, permits, PPE and rest; recorded and updated when plans change.

How to answer
  • Explain how the daily plan is made: who leads it, when, which tasks are discussed
  • Explain that hazards, permits, PPE, rest hours and other operations are considered for each task
  • Show where meetings are recorded
  • Explain how changes during the day are handled
  • Give an example of a recent planning meeting
Have ready
  • Work planning meeting records
  • Toolbox talk records
  • Permits and RAs linked to tasks
  • Rest hour records
  • Daily work plan board

5.7.5 Stop Work Authority Rotational 2

Do the Master, officers and ratings understand the purpose of the company's Stop Work Authority policy and procedure and how it is applied on board?

In one lineAnyone can stop unsafe work, without blame; we make safe, discuss, fix and restart only when it's safe.

How to answer
  • Explain that everyone, whatever rank, may and must stop work that looks unsafe
  • Describe the process: stop, make safe, inform supervisor, discuss and resolve, restart only when safe
  • Give an example where work was stopped
  • Explain that no one is blamed for using SWA in good faith
  • Explain how it is recorded (near-miss or SWA report)
Have ready
  • Stop Work Authority policy in the SMS
  • SWA posters/cards in work areas
  • Reports or near-miss entries where work was stopped
  • Safety meeting minutes discussing SWA
  • Toolbox talk / work planning records mentioning SWA

5.7.6 Risk assessments for new, non-routine, unplanned or specified tasks Rotational 2

Are the Master, officers and ratings familiar, to the extent their jobs require, with the company risk assessment procedures, and is there evidence that risk assessments are produced and reviewed as those procedures require?

In one lineIdentify hazards, rate risk, add controls, check residual risk, approve, brief the team and review generic RAs before every use.

How to answer
  • Explain the process: identify hazards, assess likelihood and consequence, add controls until residual risk is acceptable, get approval at the level the SMS requires
  • Walk the inspector through a risk assessment for a job you were involved in
  • Explain how the team is involved: discussed in toolbox meeting, everyone signs and understands the controls
  • Explain that generic risk assessments are reviewed and adjusted for each job, not just reused
  • Explain when RAs are reviewed: after incidents, near-misses, or changes
Have ready
  • Risk assessment library
  • Recent task-specific risk assessments
  • Toolbox talk records
  • Permits linked to the RA
  • RA review records after incidents

5.7.7 Safety Data Sheets Rotational 2

Are Safety Data Sheets on board for every cargo, bunker fuel, chemical, paint and other product being handled, and do crew members know how to use them?

In one lineSDS for every cargo, fuel, chemical and paint; I know hazards, PPE, first aid and spill actions from it.

How to answer
  • Explain where SDS are kept for cargo, bunkers and stores
  • Explain the key sections: hazards identification, first aid, firefighting, accidental release, handling and storage, exposure controls/PPE
  • Show the SDS for the current cargo and explain the PPE and exposure limits
  • Explain how SDS are obtained for new chemicals before use
  • Explain how SDS information is shared with crew before handling
Have ready
  • SDS for cargo on board
  • SDS for bunker fuel
  • SDS for chemicals and paints
  • Chemical inventory
  • Cargo information posted in CCR

5.7.8 Simultaneous Operations (SIMOPS) procedure Rotational 2

Do the Master, officers and ratings know the company procedure for simultaneous operations (SIMOPS), and is there evidence that SIMOPS are taken into account when work is planned and that the necessary controls stay in place throughout?

In one lineSIMOPS matrix tells us what can run together; extra controls agreed, terminal informed, stop if conditions change.

How to answer
  • Explain SIMOPS: two or more activities at the same time (e.g. cargo transfer with bunkering, storing, crew change or maintenance) that may interact and raise the risk
  • Show the SIMOPS matrix and explain one combination: allowed, allowed with extra controls, or prohibited
  • Explain the controls used: Master's approval, extra watchkeepers, permits, agreed stop criteria, communications
  • Explain how SIMOPS are agreed with the terminal and recorded in the ship/shore safety checklist
  • Give a recent example from work planning where SIMOPS were considered
Have ready
  • SIMOPS matrix
  • Work planning records
  • Risk assessments
  • Ship/shore safety checklist
  • Permits for concurrent work

5.8.1 Safety inspection of the main deck and mooring areas Core

Do the Master and officers know the company's safety inspection procedure for the main deck, including the mooring areas, and have those inspections actually picked up the health, safety and environmental hazards that exist?

In one lineDeck and mooring areas are inspected on schedule; findings like worn lines, leaks or trip hazards are recorded, reported and fixed.

How to answer
  • Explain the inspection interval, who carries it out and who reviews the checklist
  • Walk the inspector through the checklist items for the main deck and mooring areas and how findings are recorded
  • Point out snap-back zone marking and explain the mooring line inspection and brake testing routine
  • Explain how hydraulic leaks, corrosion and damaged guardrails are found and dealt with
  • Explain how defects are entered in the defect list/PMS, reported to the office and tracked to closure
Have ready
  • Completed safety inspection checklists for the main deck and mooring areas
  • Defect list / PMS entries raised from inspections
  • Mooring line inspection and brake test records
  • Mooring equipment management plan / line register
  • Photos or reports of corrective actions

5.8.2 Safety inspection of the machinery space Core

Do the Master and officers know the company's safety inspection procedure for the machinery spaces, and have those inspections been effective in picking up the health, safety and environmental hazards present there?

In one lineMachinery spaces inspected on schedule; leaks, hot surfaces, missing guards and housekeeping issues found, reported and fixed.

How to answer
  • Explain the inspection interval, who carries it out and who reviews the checklist
  • Walk the inspector through the checklist items for the machinery spaces and how findings are recorded
  • Explain how hot surfaces, oil leaks and missing insulation are checked and corrected
  • Explain how quick-closing valves and emergency stops are included in inspections and tests
  • Explain how defects are entered in the defect list/PMS, reported to the office and tracked to closure
Have ready
  • Completed safety inspection checklists for the machinery spaces
  • Defect list / PMS entries raised from inspections
  • Quick-closing valve and emergency stop test records
  • Insulation and spray shield checks
  • Engine room housekeeping and oily waste records

5.8.3 Safety inspections of the cargo pumproom Core

On oil and chemical tankers with a cargo pump room, do the Master and officers know the company's safety inspection procedure for it, and have those inspections picked up the health, safety and environmental hazards present there?

In one linePump room inspected per checklist; ventilation, gas detection, bilge alarm, glands and leaks checked, and every entry controlled.

How to answer
  • Explain the inspection interval, who carries it out and who reviews the checklist
  • Walk the inspector through the checklist items for the cargo pump room and how findings are recorded
  • Explain pump room entry precautions: ventilation running, gas readings checked, entry logged, communication with deck/CCR
  • Explain how leaks from glands and pipework and the bilge condition are checked
  • Explain how defects are entered in the defect list/PMS, reported to the office and tracked to closure
Have ready
  • Completed safety inspection checklists for the cargo pump room
  • Defect list / PMS entries raised from inspections
  • Pump room entry log
  • Ventilation and gas detection records
  • Bilge alarm test records

5.8.4 Cargo machinery rooms safety inspections Core

On gas carriers, do the Master and officers know the safety inspection procedure for the cargo machinery rooms (compressor and motor rooms), and have those inspections picked up the health, safety and environmental hazards present there?

In one lineCompressor and motor rooms inspected per checklist; ventilation, air locks, shaft seals, gas detection and leaks checked and recorded.

How to answer
  • Explain the inspection interval, who carries it out and who reviews the checklist
  • Walk the inspector through the checklist items for the cargo machinery rooms and how findings are recorded
  • Explain the air lock alarm and door arrangement and why the motor room is kept at overpressure
  • Explain how bulkhead shaft seals and compressor leaks are checked
  • Explain how defects are entered in the defect list/PMS, reported to the office and tracked to closure
Have ready
  • Completed safety inspection checklists for the cargo machinery rooms
  • Defect list / PMS entries raised from inspections
  • Ventilation and gas detection records
  • Air lock alarm test records
  • Bulkhead seal maintenance records

5.8.5 Safety inspection of the forecastle spaces Core

Do the Master and officers know the company's safety inspection procedure for the forecastle, and have those inspections picked up the health, safety and environmental hazards present there?

In one lineForecastle inspected per checklist; stores secured, enclosed spaces controlled, windlass and hydraulics checked.

How to answer
  • Explain the inspection interval, who carries it out and who reviews the checklist
  • Walk the inspector through the checklist items for the forecastle spaces and how findings are recorded
  • Explain that the chain locker and some forward spaces are enclosed spaces needing a permit
  • Explain checks on windlass, brakes, stoppers and hydraulic systems
  • Explain how defects are entered in the defect list/PMS, reported to the office and tracked to closure
Have ready
  • Completed safety inspection checklists for the forecastle spaces
  • Defect list / PMS entries raised from inspections
  • Forecastle store inventory
  • Windlass/brake maintenance records
  • Enclosed space list

5.8.6 Safety inspections of the accommodation spaces Rotational 1

Do the Master and officers know the company's safety inspection procedure for the accommodation, and have those inspections picked up the health, safety and environmental hazards present there?

In one lineAccommodation inspected per checklist; electrical, fire, hygiene and escape hazards found, recorded and corrected.

How to answer
  • Explain the inspection interval, who carries it out and who reviews the checklist
  • Walk the inspector through the checklist items for the accommodation and how findings are recorded
  • Explain the checks for unauthorised electrical appliances, extension cords and smoking areas
  • Explain galley, laundry and hospital checks
  • Explain how defects are entered in the defect list/PMS, reported to the office and tracked to closure
Have ready
  • Completed safety inspection checklists for the accommodation
  • Defect list / PMS entries raised from inspections
  • Accommodation inspection records
  • Galley duct cleaning records
  • Hygiene inspection records

5.8.7 Ballast and/or bunker pumproom safety inspection Rotational 2

Where the ship has a separate ballast and/or bunker pump room, do the Master and officers know the company's safety inspection procedure for it, and have those inspections picked up the health, safety and environmental hazards present there?

In one lineBallast/bunker pump room inspected per checklist; ventilation, gas checks, leaks and bilges controlled and recorded.

How to answer
  • Explain the inspection interval, who carries it out and who reviews the checklist
  • Walk the inspector through the checklist items for the ballast and/or bunker pump room and how findings are recorded
  • Explain the entry precautions and gas checks before entry
  • Explain how leaks and bilge conditions are checked
  • Explain how defects are entered in the defect list/PMS, reported to the office and tracked to closure
Have ready
  • Completed safety inspection checklists for the ballast and/or bunker pump room
  • Defect list / PMS entries raised from inspections
  • Pump room entry records
  • Gas readings before entry
  • Bilge alarm test records

5.9.1 Lifting and rigging equipment procedures, maintenance and inspection Rotational 1

Do the Master, officers and ratings know the company procedures for lifting and rigging, and is there evidence that every item of lifting and rigging gear has been maintained, inspected and tested as the procedure requires?

In one lineEvery item in the register, marked with ID and SWL, certified and inspected; check before use and quarantine anything damaged.

How to answer
  • Explain the markings each item must carry and show an example (SWL, ID, colour code)
  • Describe pre-use checks: certificate and marking, visual check for wear, deformation, cracks, broken wires, correct shackle pin
  • Show the lifting gear register and how items are linked to certificates and inspection dates
  • Explain that damaged or unmarked gear is quarantined and removed, not used
  • Explain how lifts are planned: load weight known, gear rated above it, banksman, tag lines, nobody under the load
Have ready
  • Lifting appliance and loose gear register
  • Test certificates for loose gear
  • Crane/overhead crane thorough examination reports
  • Pre-use inspection records
  • Quarantine area for condemned gear
  • Lifting risk assessments

5.9.2 Spare parts for a single cargo hose handling crane Rotational 2

Where the ship has only one crane for handling cargo hoses, is there a risk assessment identifying the minimum spare parts needed to keep it working if a single component fails, and are those spares on board?

In one lineRA identifies critical crane parts; minimum spares listed and on board; PMS inventory matches.

How to answer
  • Explain that with only one hose crane a single failure can stop cargo operations, so a risk assessment was made to identify critical components
  • Name the critical items identified (e.g. hydraulic hoses, seals, solenoid/control valves, limit switches, hoist wire, motor contactor) and the minimum quantity required
  • Show the physical spares in the store and that their part numbers match the crane
  • Explain how the minimum stock is kept: PMS minimum level, requisition when used
  • Explain the contingency if the crane still fails: inform terminal and office, shore crane or alternative hose handling arrangements
Have ready
  • Risk assessment for the single hose handling crane
  • Minimum critical spares list
  • Spares in the store with part numbers
  • PMS spare parts inventory with minimum levels
  • Crane maintenance and inspection records

5.10.1 Pilot boarding arrangements Rotational 1

Do the Master and the deck officers and ratings know how the company requires the pilot boarding arrangements to be rigged, and is the equipment in good condition and used according to industry best practice?

In one lineCertified ladder, secured to strong points at the right height, officer in attendance with radio, lifebuoy and light ready.

How to answer
  • Walk through rigging: ladder inspected, correct number of steps over the side, secured at the right height, side ropes made fast to strong points
  • Explain the combination ladder arrangement when freeboard requires it
  • Explain the responsible officer's duties: present on deck, communication with bridge, lifebuoy and heaving line ready, lighting at night
  • Describe checks before use and recovery: steps, ropes, spreaders, securing devices
  • Explain maintenance and the record kept for each ladder
Have ready
  • Pilot ladder certificate and ID
  • Pilot ladder inspection/log record
  • IMO/IMPA pilot boarding arrangement poster
  • Lifebuoy with light and heaving line
  • Combination arrangement components
  • Lighting at boarding position

5.10.2 Accommodation ladders Rotational 2

Do the Master and the deck officers and ratings know how the company requires the accommodation ladders to be rigged, and are the ladders in good condition and used according to company procedure and the maker's instructions?

In one lineInspect, lower under control, angle within limits, net and lifebuoy rigged; annual exam and five-yearly test on record.

How to answer
  • Walk through rigging: inspect, lower under control, set the angle within the marked limit, fit the stanchions and handrails, rig safety net
  • Explain how the lower platform is kept horizontal and the height above water when used with a pilot ladder
  • Explain safety equipment: lifebuoy with line, lighting at night
  • Explain the inspection, maintenance and wire renewal records
  • Explain safe recovery: no persons on the ladder, winch control
Have ready
  • Accommodation ladder inspection records
  • Thorough examination and load test certificates
  • Wire renewal records
  • Maker's manual
  • Safety net and lifebuoy

5.10.3 Safe access to the vessel while alongside a terminal/berth Rotational 2

Do the Master, officers and ratings know the company procedure for safe access while alongside a terminal or berth, and is safe access being provided by the ship's gangway, accommodation ladder or a shore gangway?

In one lineAccess rigged and secured, net and lifebuoy in place, adjusted for tide and draft, watched at all times.

How to answer
  • Explain who rigs and checks the access on arrival and how often the duty officer/watch rechecks it
  • Explain how the gangway or ladder is adjusted as draft and tide change so it stays within its safe angle and secured at both ends
  • Describe the gangway watch: visitor log and ID check, safety briefing and PPE for visitors, security level measures
  • Explain the portable gangway: certificate, SWL and maximum angle marking, rollers/wheels free on the quay, safety net under its full length
  • Explain what is done if shore access is unsafe: stop access, report to terminal, record in the ship/shore safety checklist
Have ready
  • Gangway or accommodation ladder as rigged
  • Safety net under the full length
  • Lifebuoy with line at the gangway
  • Gangway/visitor log
  • Portable gangway certificate and SWL marking
  • Ship/shore safety checklist

5.10.4 Personnel transfer by crane Rotational 2

Where personnel are transferred by crane, do the Master and officers know the company procedure for it, and where a personnel transfer basket and accessories are provided, are they in good condition and used as the company and maker require?

In one lineTransfer only with RA and approval; certified basket and crane, lifejackets, communications and a contingency plan.

How to answer
  • Explain the company requirements: personnel transfer only when no safer means exists, approved by the Master, with a risk assessment and toolbox talk
  • Describe the checks on the basket/transfer device: certificate, SWL, inspection date, net and frame condition, hook with safety latch, tag lines
  • Explain the crane checks: certified for the load, limit switches and brakes tested, operator competent, signaller in sight
  • Explain PPE and communications: lifejackets, helmets, radio contact between crane operator, signaller and both decks; weather and sea state limits
  • Explain the contingency if the crane fails with persons suspended: emergency lowering, rescue boat on standby where required
Have ready
  • Company personnel transfer procedure
  • Risk assessment and toolbox talk record
  • Personnel transfer basket certificate and inspection records
  • Crane certificate and pre-use checks
  • Lifejackets and radios
  • Emergency lowering instructions for the crane

5.10.5 Helicopter operations Rotational 2

Where helicopter operations take place, do the Master and officers know the company procedures for ship/helicopter operations, and is there evidence those procedures were followed?

In one lineICS guide and company checklist followed: area cleared and marked, venting stopped, fire and rescue parties ready, comms agreed.

How to answer
  • Explain the preparation: checklist completed, Master's briefing, communication channel agreed with the pilot, relative wind and heading as requested
  • Describe the deck team: helicopter landing officer, hook handler, fire party with foam monitors/applicators and DCP, rescue party with crash kit
  • Explain that cargo operations and venting are stopped and the tank pressure condition is checked before the helicopter arrives
  • Explain how loose items are secured and the operating area cleared and marked
  • Show checklists from the last helicopter operation
Have ready
  • ICS Guide to Helicopter/Ship Operations
  • Company helicopter operations procedure
  • Completed ship/helicopter checklists
  • Crash kit and firefighting equipment for the operating area
  • Operating area markings and lighting
  • Helicopter drill records

5.10.6 Helicopter facilities Rotational 2

On ships fitted with helicopter facilities, do the Master and officers know the company procedures for ship/helicopter operations, and have the crew who take part received suitable training?

In one lineHelicopter team trained and drilled; deck area marked and lit; firefighting and crash kit ready; ICS guide followed.

How to answer
  • Explain who is trained for helicopter operations and how training is done and recorded
  • Describe the firefighting and rescue equipment for the helicopter area and where it is stored
  • Explain the roles in the helicopter team and the checklist used
  • Describe the last helicopter emergency drill
  • Explain inspection of the helideck/winching area and its markings
Have ready
  • Helicopter operations training records
  • Helideck/winching area and markings
  • Helicopter area firefighting equipment and crash kit
  • Drill records
  • ICS Guide to Helicopter/Ship Operations and company checklists

5.10.7 Escape routes Rotational 1

Do the Master, officers and crew know how to escape from the engine room, pump rooms, compressor rooms and accommodation and, when in port, how to get off the ship, and are those routes clearly marked, kept clear and well lit?

In one lineI can lead you out from my workplace by the marked route; doors open from inside, routes clear and lit.

How to answer
  • Walk the inspector along an escape route from your work area to the open deck or muster station
  • Show that escape doors open from inside without keys
  • Explain how the fire team gets through a secured external door from outside (e.g. key box, lock arrangements in the SMS)
  • Explain the in-port arrangement for leaving the ship if the gangway is cut off, e.g. a ladder or lifeboat/liferaft ready on the offshore side, as the terminal and company require
  • Explain checks of escape route lighting and markings during safety rounds
Have ready
  • Fire control/safety plan showing escape routes
  • Escape route signs and markings
  • Escape trunk from engine room
  • Emergency lighting on routes
  • EEBDs on escape routes
  • Safety inspection records

5.11.1 Cargo and bunker sample management Rotational 2

Do the Master and officers know the company procedures for managing bunker fuel samples and samples of MARPOL Annex I and/or II cargoes as applicable, and are samples correctly stored and finally disposed of?

In one lineBunker samples kept 12 months, cargo samples in a ventilated locker in the cargo area, logged, and disposed ashore.

How to answer
  • Explain which samples are kept: bunker (MARPOL Annex VI) samples with seal numbers recorded on the BDN, and cargo samples taken at loading and discharge as the company and charterer require
  • Show where samples are stored and explain the locker: in the cargo area, ventilated, bottles secured in racks, firefighting means nearby
  • Explain retention periods (bunker samples at least 12 months; cargo samples per company procedure) and disposal ashore, never overboard
  • Show the sample register with dates, seal numbers, retention end date and disposal record
  • Explain how samples of incompatible cargoes are segregated and labelled with the product name and hazards
Have ready
  • Cargo sample locker
  • Bunker samples with seal numbers matching the BDN
  • Sample register / log
  • Shore disposal receipts
  • Company sample management procedure
  • SDS for sampled products

5.12.1 Respiratory protective equipment Rotational 2

Do the Master, officers and ratings know the company procedures on respiratory protection during cargo operations, and do those procedures forbid filter-type respirators for this purpose?

In one lineSupplied-air only (SCBA/airline) for cargo work; filter respirators are not used; escape sets ready for toxic cargoes.

How to answer
  • Explain that only supplied-air equipment (SCBA or airline) is used for cargo operations where respiratory protection is needed
  • Explain why filter respirators are not allowed: they don't supply oxygen and can be overwhelmed by high vapour levels
  • Explain the emergency escape sets for toxic cargo
  • Show the BA sets and their condition
  • Explain the breathing apparatus training and drills you have done on board
Have ready
  • Company procedure on respiratory protection during cargo operations
  • SCBA sets and spare cylinders
  • Airline breathing apparatus where provided
  • Emergency escape breathing sets for toxic cargoes
  • Respiratory equipment inspection and training records

5.12.2 Decontamination showers and eyewash stations Rotational 2

On chemical tankers and LPG carriers, do the Master, officers and ratings know where the deck decontamination showers and eyewash stations are and how to use them, and are these facilities clearly marked, easy to reach and ready for use?

In one lineShowers and eyewash by the manifold, marked, tested and freeze-protected; flush at least 15 minutes.

How to answer
  • Point out the shower and eyewash nearest the manifold and your work position
  • Explain operation: pull the handle or push the plate, remove contaminated clothing, flush for at least 15 minutes
  • Explain the test routine: flow tested at the company interval, water clean, recorded
  • Explain freeze protection: heat tracing, draining or other arrangement in cold weather
  • Explain first aid for the current cargo using the SDS and when to seek medical advice
Have ready
  • Deck decontamination showers and eyewashes
  • Weekly/periodic test records in the PMS
  • Signage and marking of each station
  • SDS for the current cargo (first aid section)
  • Freeze protection (heat tracing or drains) where fitted
  • First aid / chemical exposure kit

An independent guide written by seafarers for seafarers. It is not affiliated with or endorsed by OCIMF and does not reproduce the SIRE 2.0 Question Library: questions are put in our own words. The official library and guidance are published by OCIMF (ocimf.org). Always follow your company's SMS.