5.6.6 Oxygen sensors in inert gas system spaces
Rotational 2ChemicalOilAsked to: Master, Chief Officer, 2nd / 3rd OfficerWhere: Engine Control Room, Engine RoomOnly if it applies to the ship
On oil and chemical tankers, do the Master and officers know how to operate and maintain the oxygen sensors and alarms in the compartment(s) housing the inert gas plant, and is that equipment fully working with sensors calibrated and alarm points correctly set?
In one lineO2 sensors in the IG space warn of leaks; alarm set and tested; on alarm evacuate and do not enter without BA.
How to answer
- Explain where the sensors are and why: leaking inert gas or nitrogen can displace oxygen without warning
- State the alarm set point and where the alarm sounds (in the space, at the entrance, CCR/bridge)
- Describe calibration and test routine, using clean fresh air (20.9% O2) as the reference point and nitrogen or a certified test gas for the low point, as the maker specifies
- Describe actions on alarm: do not enter, evacuate, ventilate, investigate the leak, re-enter only after testing or with BA
- Show the calibration and alarm test records
What the inspector looks for
- Oxygen-depletion sensors fitted in the IG generator/fan room or nitrogen generator space
- Alarm set points (commonly 19.5% O2 low; confirm with maker and company) and audible/visual alarms inside and outside the space
- Calibration of sensors with records and in-date calibration gas
- Periodic functional tests of the alarms
- Officers' awareness of the asphyxiation risk from IG or nitrogen leakage
Have ready to show
- Oxygen sensors and alarm panel
- Calibration records and calibration gas
- Alarm functional test records
- Maker's manual for the sensors
- PMS entries for the O2 monitoring system
Avoid
- Sensors not calibrated at the maker's interval
- Alarm not audible or indicator not working
- Officers unaware the sensors exist
- Entering the space while the alarm is active
← 5.6.5 Cargo pump room fixed gas detection system5.7.1 Incident investigation reports for defined incidents →
Practise in the interview trainer All questions
An independent guide written by seafarers for seafarers. It is not affiliated with or endorsed by OCIMF and does not reproduce the SIRE 2.0 Question Library: questions are put in our own words. The official library and guidance are published by OCIMF (ocimf.org). Always follow your company's SMS.