SeaVint

5.6.4 Fixed gas detection system required by the IGF Code

Rotational 1ChemicalLPGOilAsked to: Master, Chief Officer, 2nd / 3rd OfficerWhere: Bridge, Engine Control RoomOnly if it applies to the ship

On ships using gas as fuel under the IGF Code, do the Master and officers know where the fixed gas detection system is, its purpose and operation, and is it in good order, maintained and calibrated in line with company procedures and the maker's instructions?

In one lineDetectors cover all gas fuel spaces and ducts; I know the alarm and shutdown points; tested, calibrated and bypasses controlled.

How to answer

  • Explain the spaces monitored and where the panels and alarms are
  • State the alarm and shutdown set points for your ship and what happens automatically at each (e.g. master gas valve closes, ventilation changes)
  • Describe the routine tests of shutdown functions and how they are recorded
  • Describe zero/span calibration routine and who does the shore service
  • Explain that bypasses need authorisation, are logged and are removed as soon as possible

What the inspector looks for

  • Detection in tank connection spaces, fuel preparation rooms, bunker stations, ventilated ducts/annular spaces of double-walled pipes and machinery spaces as applicable
  • Alarm and automatic shutdown set points as stated in the fuel-handling manual and maker's documentation
  • Periodic tests of the gas safety system and automatic shutdowns
  • Calibration records and in-date span gas
  • Control of bypasses and inhibits

Have ready to show

  • Fuel-handling manual
  • Gas detection and gas safety system panels
  • Calibration and span gas records
  • Shutdown test records
  • Bypass/inhibit log
  • PMS records

Avoid

  • Detectors bypassed or inhibited without control
  • Detector calibration overdue
  • Shutdown tests not done
  • Officers unaware of the set points

Practise in the interview trainer All questions

An independent guide written by seafarers for seafarers. It is not affiliated with or endorsed by OCIMF and does not reproduce the SIRE 2.0 Question Library: questions are put in our own words. The official library and guidance are published by OCIMF (ocimf.org). Always follow your company's SMS.