SeaVint

5.2.4 Machinery space fixed carbon dioxide fire extinguishing system

Rotational 1ChemicalLNGLPGOilAsked to: Master, Chief Officer, 2nd / 3rd Officer, Engineer officersWhere: Aft Mooring Deck, Emergency Headquarters.Only if it applies to the ship

Where machinery spaces are protected by fixed CO2, do the Master and officers know where the system is, its purpose and how to release it, and is it ready to use at once, with release steps and operating guidance posted at each control position?

In one lineHead count, close openings, stop fans and fuel, open cabinet for alarm, release with both controls; CO2 room clear and serviced.

How to answer

  • Walk through the release: Master's decision, head count of the engine room, stop ventilation and close all openings and dampers, stop fuel pumps (quick-closing valves), open release cabinet (alarm sounds), operate the two separate controls
  • Explain that the space is not reopened until cooled and confirmed safe, and re-entry only with BA
  • State the precautions for entering the CO2 room: check ventilation is running, inform the bridge, never alone
  • Explain maintenance: periodic contents checks by weight or liquid level, inspection of pipework, hoses and actuators, annual service by approved firm
  • Explain where the release controls are and who holds the keys

What the inspector looks for

  • Officers' knowledge of the full release sequence and the safety interlocks
  • Pre-discharge audible/visual alarm and automatic ventilation shutdown
  • CO2 room condition: direct access from open deck, ventilation, lighting, not used for storage
  • Operating instructions posted at the release cabinets and CO2 room
  • Maintenance and servicing records (e.g. contents checks, hose and valve inspections, shore service)

Have ready to show

  • CO2 room, cylinders and control heads
  • Release cabinets with posted instructions
  • Shore service certificate/report
  • Onboard inspection records in the PMS
  • Fire control plan
  • Engine room head-count arrangements

Avoid

  • Instructions missing or unreadable at the release station
  • CO2 room used as a store or ventilation faulty
  • Officers forgetting the head count or closing openings
  • Overdue servicing or contents checks

Practise in the interview trainer All questions

An independent guide written by seafarers for seafarers. It is not affiliated with or endorsed by OCIMF and does not reproduce the SIRE 2.0 Question Library: questions are put in our own words. The official library and guidance are published by OCIMF (ocimf.org). Always follow your company's SMS.