SeaVint

8.3.16 Inert gas system non-return devices

Rotational 2ChemicalOilAsked to: Master, Chief Officer, 2nd / 3rd OfficerWhere: Cargo Control Room, Main DeckOnly if it applies to the ship

Can the Master and officers explain the job of the IG system's non-return devices (deck seal and non-return valve), how they work, how they are tested and maintained, and are these devices in good condition?

In one lineDeck seal and non-return valve stop gas backflow; check water level and alarm, inspect and overhaul per PMS.

How to answer

  • Explain that the non-return devices stop hydrocarbon gas and cargo from flowing back to the IG plant and machinery spaces.
  • Describe the deck seal type fitted and how water is supplied, how the level is checked and how the low-level alarm is tested.
  • Explain the maintenance: opening up and inspecting the deck seal for corrosion, float and demister condition, and overhaul of the non-return valve per PMS.
  • Describe cold weather measures to prevent freezing.
  • Show the latest inspection records.

What the inspector looks for

  • Deck water seal type (wet, semi-dry or dry) and its operation
  • Mechanical non-return valve and deck isolating valve condition
  • Deck seal water level alarm and heating/antifreeze arrangements
  • Inspection and overhaul records in the PMS

Have ready to show

  • Deck seal and non-return valve PMS records
  • Deck seal level alarm test records
  • IGS diagram
  • Maker's manual
  • Inspection reports with photos if available

Avoid

  • Deck seal water supply or level alarm not working
  • Corroded or leaking non-return valve
  • No record of internal inspection

Practise in the interview trainer All questions

An independent guide written by seafarers for seafarers. It is not affiliated with or endorsed by OCIMF and does not reproduce the SIRE 2.0 Question Library: questions are put in our own words. The official library and guidance are published by OCIMF (ocimf.org). Always follow your company's SMS.