8.4.5 Escape sets as required by the IGC Code
Rotational 2LPGAsked to: Chief Officer, 2nd / 3rd Officer, Chief Engineer, Engineer officers, RatingsWhere: Engine Room, Internal Accommodation, Interview - Rating
Does the gas carrier have enough IGC Code emergency escape sets for everyone on board, and do the sets protect both breathing and eyes?
In one lineOne self-contained escape set per person, eye and breathing protection, in date and charged.
How to answer
- State how many escape sets are on board, where they are, and confirm one for everyone.
- Explain why the type is suitable: self-contained air supply with hood for at least 15 minutes, giving eye and breathing protection.
- Demonstrate donning the set.
- Explain the checks and service schedule.
What the inspector looks for
- Number of sets against persons on board
- Type of set (self-contained air sets; filter types are not acceptable)
- Locations and crew familiarity
- Cylinder pressure and service records
Have ready to show
- Escape sets in cabins and work areas
- Escape set inventory list
- Pressure check and service records
- Drill records
Avoid
- Fewer sets than persons on board
- Filter-type sets used
- Low pressure or expired sets
Practise in the interview trainer All questions
An independent guide written by seafarers for seafarers. It is not affiliated with or endorsed by OCIMF and does not reproduce the SIRE 2.0 Question Library: questions are put in our own words. The official library and guidance are published by OCIMF (ocimf.org). Always follow your company's SMS.