8.4.7 Vent outlet protection screens or flame screens
Rotational 2LPGAsked to: Master, Chief Officer, 2nd / 3rd OfficerWhere: Main Deck
Are the cargo containment vent outlets fitted with the protection screen or flame screen that the carried cargo requires, and are those screens in good condition?
In one lineCorrect screen type for the cargo, intact and clear, inspected per PMS with spares on board.
How to answer
- Explain which cargoes on your Certificate of Fitness need flame screens at the vent outlets and which only need protection screens against foreign objects.
- Describe how and how often the screens are inspected and replaced, and who does it.
- Explain precautions in cold weather and after mast fires or venting, when screens can be blocked or damaged.
- Show the inspection record and spare screens.
What the inspector looks for
- Type of screen fitted at each vent outlet and whether any certified cargo needs flame screens under the IGC Code
- Screen condition: corrosion, holes, distortion, blockage by debris or ice
- Spare screens on board and ease of renewal
- Inspection records in the PMS
Have ready to show
- Vent mast outlet screens (photographs if access is restricted)
- Certificate of Fitness cargo list
- IGC Code product requirements
- PMS inspection records
- Spare screens in store
Avoid
- Damaged or corroded screens
- Protection screen fitted where a flame screen is required
- No inspection record
Practise in the interview trainer All questions