8.6.14 Reliquefaction plant
Rotational 2LNGLPGAsked to: Master, Chief Officer, 2nd / 3rd OfficerWhere: Cargo Control Room, Compressor RoomOnly if it applies to the ship
Where a reliquefaction plant is fitted, do the Master and officers know the company procedures for running and maintaining it safely, and is it in good condition?
In one lineKnow the plant, test trips and alarms, purge non-condensables to the vent mast, maintain per PMS.
How to answer
- Explain the type of plant and how it is started, run and stopped.
- List the trips and alarms and explain how they are tested.
- Explain how non-condensable gases are purged safely to the vent mast.
- Describe the precautions for cargo-specific issues, e.g. polymerisation in compressors with inhibited cargoes.
- Show maintenance and test records.
What the inspector looks for
- Type of plant (direct or cascade cycle on LPG, nitrogen-expansion or mixed refrigerant on LNG) and its operation
- Safety trips and alarms: high discharge temperature/pressure, low suction pressure, low lube oil pressure, high liquid level in separators
- Purging of non-condensable gases
- Maintenance and test records
Have ready to show
- Reliquefaction plant manual
- Trip and alarm test records
- PMS records
- Plant operating log
- Cargo System Operation Manual
Avoid
- Trips not tested or bypassed
- Poor maintenance of compressors
- Unsafe purging of non-condensables