Do the Master and officers know the company procedures for operating, inspecting, testing and maintaining the gas carrier's inert gas or nitrogen generating plant and its associated equipment, and is it in good condition?

In one lineDeliver IG or nitrogen only within O2 and dew point limits, test alarms, ventilate the plant room, respect asphyxiation risk.

How to answer

  • Explain what the plant is used for on board and the oxygen and dew point limits you work to.
  • Describe starting, checking purity and delivering only when within limits.
  • Explain alarm/trip tests and analyser and dew point meter calibration.
  • Describe the dangers of nitrogen leaks and oxygen-enriched exhaust and the room precautions (ventilation, oxygen monitor, signs).
  • Show maintenance records.

What the inspector looks for

  • Type of plant (oil-fired IG generator and/or nitrogen generator) and its use (inerting tanks, hold spaces, purging lines)
  • Oxygen and dew point limits of the gas produced
  • Alarm and shutdown tests and analyser calibration
  • Hazards of nitrogen leaks (oxygen deficiency) and oxygen-enriched exhaust
  • Maintenance records

Have ready to show

  • IG/nitrogen plant manual
  • Alarm test and calibration records
  • Oxygen and dew point records
  • PMS records
  • Room oxygen monitor and warning signs

Avoid

  • Plant not maintained or alarms untested
  • Crew unaware of nitrogen and oxygen-enriched exhaust hazards
  • Dew point not monitored