8.99.4 Cargo and ballast valve testing
Rotational 1ChemicalLNGLPGOilAsked to: Master, Chief Officer, 2nd / 3rd OfficerWhere: Cargo Control Room, Main Deck
Do the Master and officers know how the company requires the valves of the cargo and ballast systems to be checked and tested, and are the valves and their remote control system in good working order?
In one lineTest valves before operations, compare remote and local indication, know how to operate valves with the hand pump.
How to answer
- Explain the valve test done before cargo operations and how results are recorded.
- Describe how remote indicators are checked against local indicators.
- Demonstrate operating a valve with the portable or local hand pump, or explain the emergency control mode fitted.
- Explain how defects are reported and how a valve with a defect is controlled until repaired.
- Show the records.
What the inspector looks for
- Pre-operation valve operation tests and recorded closing/opening times
- Accuracy of remote position indicators compared with the actual valve position
- Emergency operation using the local hand pump or manual override
- Hydraulic power pack condition, leaks and oil levels
- Defects recorded and repaired
Have ready to show
- Valve test records
- Hydraulic remote control system manual
- Portable/local hand pump and connection points
- PMS records for valves and actuators
- Defect reports
Avoid
- Valves not tested before operations
- Remote indicators wrong
- Crew unable to operate valves in emergency mode
Practise in the interview trainer All questions