Condensate does not drain under load
Atlas Copco MAS GA 18, oil-filled screw compressor
Possible cause
Drain line clogged
What to do
Manufacturer's manual, p. 92Inspect and clean
See the assembly on the 3D model
Other Atlas Copco MAS GA 18 faults
Compressor starts but does not loadFaulty solenoid valve / stuck intake valve / leak in control lines / non‑sealing minimum‑pressure valveCompressor does not unload, safety valve tripsFaulty solenoid valve or intake valve does not closePerformance or pressure below normalFlow exceeds capacity, air filter clogged, solenoid valve faulty, leaks, intake valve not fully open, safety valve chokedElevated oil consumption, oil carried into the lineIncorrect oil (foaming), over‑filling, oil separator faulty, oil return line defectiveSafety valve trips after loadFaulty intake valve, minimum‑pressure valve or safety valve itself; oil separator cloggedHigh temperature at block outlet or air outletLow oil, insufficient cooling air, oil or air cooler clogged, bypass (thermostatic) valve faultyCompressor does not start, engine overload displayed on screenIncorrect phase sequence