High temperature at block outlet or air outlet
Atlas Copco MAS GA 18, oil-filled screw compressor
Possible cause
Low oil, insufficient cooling air, oil or air cooler clogged, bypass (thermostatic) valve faulty
What to do
Manufacturer's manual, p. 93Top up oil, improve ventilation and eliminate recirculation, clean coolers, check valve
See the assembly on the 3D model
Other Atlas Copco MAS GA 18 faults
Compressor starts but does not loadFaulty solenoid valve / stuck intake valve / leak in control lines / non‑sealing minimum‑pressure valveCompressor does not unload, safety valve tripsFaulty solenoid valve or intake valve does not closeCondensate does not drain under loadDrain line cloggedPerformance or pressure below normalFlow exceeds capacity, air filter clogged, solenoid valve faulty, leaks, intake valve not fully open, safety valve chokedElevated oil consumption, oil carried into the lineIncorrect oil (foaming), over‑filling, oil separator faulty, oil return line defectiveSafety valve trips after loadFaulty intake valve, minimum‑pressure valve or safety valve itself; oil separator cloggedCompressor does not start, engine overload displayed on screenIncorrect phase sequence