SeaVint

Safety valve trips after load

Atlas Copco MAS GA 18, oil-filled screw compressor

Possible cause

Faulty intake valve, minimum‑pressure valve or safety valve itself; oil separator clogged

What to do

Check valves, replace safety valve or oil-separator element

Manufacturer's manual, p. 93

See the assembly on the 3D model

Other Atlas Copco MAS GA 18 faults

From the manufacturer's manual “MAS18P-100 APB 440-460V 60 FM - ITJ396636 - Instruction Book”. Check against the original on board before work.

This page was translated automatically from the manual summary. Part numbers, codes and page numbers are as in the original.