SeaVint

Exhaust temperature rises on all cylinders

MAN B&W L23/30H — technical information, four-stroke auxiliary diesel engine (generating set)

Posibleng sanhi

Charge air cooler ineffective, fouled air/gas passages, poor fuel, wrong camshaft position

Ano ang gagawin

Clean coolers and filters, water-wash turbine, check Pmax and camshaft

Manual ng gumawa, p. 37

Tingnan ang assembly sa 3D model

Iba pang sira ng MAN B&W L23/30H — technical information

Mula sa manual ng gumawa na “MAN L23-30H technical information”. Suriin ang orihinal sa barko bago magtrabaho.