Draught failure alarm
TeamTec Golar OG 200, brodsko spalionica (uljni mulj, mulj otpadnih voda i kruti otpad)
Mogući uzrok
Low furnace negative pressure, damper in manual, controller settings, blown fuse, faulty controller or damper motor
Što učiniti
Priručnik proizvođača, str. 46Set damper to Auto, check controller values and fuses, replace controller or damper motor
Ostali kvarovi TeamTec Golar OG 200
Flame failure alarm at startNo ignition spark, diesel solenoids not opening, dirty nozzle, too much primary air, dirty photo resistor, poor oilFlame failure when stage 2 startsToo much primary air, damper opening too earlyLow diesel oil pressure alarmNo oil supply, faulty pressure switch b13, pump problemFlue gas temperature high alarmAbove set value (normal 400 °C), faulty controller u1 or thermocoupleCombustion chamber temperature high alarmAbove 1200 °C, faulty controller u2 or thermocoupleSludge dosage valve does not startCirculating pump off, chamber below 600 °C, relay, inverter or motor faultSludge dosage valve stops after a whileChamber temperature falls (wet sludge) or motor overload (OL2 on inverter)No flame from the sludge burnerSteam/air solenoid, low atomising pressure, too much water or air, damaged sludge nozzleLow sludge / steam pressure alarmSludge below 0.5–1 bar or steam/air below 6–9 bar, closed valves, faulty switchesFlue gas fan does not startTripped breaker e11, contactor, motor or switch
Prema priručniku proizvođača „EM-10 INCINERATOR”. Prije rada provjerite izvornik na brodu.
Stranica je automatski prevedena. Brojevi dijelova, kôdovi i stranice su kao u izvorniku.