SeaVint

10.2.6 Emergency compressed air machinery starting system

Rotational 2ChemicalLNGLPGOilAsked to: Chief Engineer, Engineer officersWhere: Engine RoomOnly if it applies to the ship

Where an emergency air compressor and emergency air receiver are provided, do the engineers know the company procedures for running, inspecting and testing them, and is the equipment in good condition?

In one lineThe emergency compressor and receiver are tested under the PMS; I can charge the receiver and start a generator from dead ship.

How to answer

  • Explain the purpose: to get the first generator running from a dead-ship condition without help from outside
  • Describe starting the emergency compressor (hand-crank or emergency power) and charging the emergency receiver
  • Walk through starting a diesel generator from the emergency receiver and restoring main power
  • State test frequency and when it was last done, and how the receiver is drained and checked

What the inspector looks for

  • Emergency compressor starts by its independent means (hand-started diesel or emergency switchboard)
  • Emergency air receiver kept charged, drained, with valves and safety valve in good order
  • Regular test records in the PMS
  • Engineers can describe a dead-ship start of a generator using emergency air
  • Operating instructions posted at the compressor

Have ready to show

  • Emergency air compressor and its starting arrangement
  • Emergency air receiver, pressure gauge and drain
  • PMS records of tests and maintenance
  • Dead-ship start procedure posted in the engine room
  • Safety valve test records

Avoid

  • Emergency compressor that will not start or has not been tested
  • Emergency receiver empty or isolated
  • Engineers unfamiliar with the dead-ship start procedure

Practise in the interview trainer All questions

An independent guide written by seafarers for seafarers. It is not affiliated with or endorsed by OCIMF and does not reproduce the SIRE 2.0 Question Library: questions are put in our own words. The official library and guidance are published by OCIMF (ocimf.org). Always follow your company's SMS.