10.3.1 Switchboard deck insulation
Rotational 2ChemicalLNGLPGOilAsked to: Chief Engineer, Engineer officersWhere: Engine Control Room, Engine Room
Are insulating mats fitted on the deck in front of and behind the electrical switchboards, and are they in good condition?
In one lineApproved insulating mats cover the deck front and rear of every switchboard; they are kept clean, undamaged and checked during inspections.
How to answer
- Explain that the mats protect people working on live equipment from electric shock
- Describe how you inspect mats during rounds and include them in PMS checks
- Confirm replacement mats are of the correct insulating grade
- Show that the area behind the switchboard is kept clear and locked or restricted as required
What the inspector looks for
- Insulating mats or gratings fitted to the front and rear of main and emergency switchboards and other open panels
- Mats undamaged, not oil-soaked, not worn through, properly fitted with no gaps
- Mats are of an electrically insulating type suitable for the voltage
- Access behind switchboards clear and not used for storage
Have ready to show
- Insulating mats at main and emergency switchboards
- Specification/certificate of insulating mat material if available
- Rear of switchboard area
- PMS or electrical inspection records
Avoid
- Damaged, missing or oil-contaminated mats
- Ordinary rubber or non-insulating mats used
- Stores or rubbish behind switchboards
← 10.2.6 Emergency compressed air machinery starting system10.3.2 Electrical distribution system switchboard earth monitoring →