SeaVint

6.1.5 Ozone Depleting Substances Record Book

Rotational 1ChemicalLNGLPGOilAsked to: Master, Chief Engineer, Engineer officersWhere: Chief Engineer's Office, Documentation, Engine Control Room

Do the Master and engineers know the company procedure for keeping the Ozone-depleting Substances Record Book, whether paper or electronic, and does it correctly log every recharge, repair, release and landing of these substances as MARPOL Annex VI requires?

In one lineEvery recharge, repair, leak and landing of ODS is logged in kg, and the equipment list matches the IAPP Supplement.

How to answer

  • Name the systems on board that contain ODS, such as the provision plant or AC with R22, and any halon or other ODS fire systems, and state that they agree with the IAPP Supplement
  • Explain that every top-up is entered with the quantity and the reason, and that repeated top-ups trigger leak detection and repair
  • Explain that recovered gas is collected in cylinders and landed ashore with a receipt. Deliberate venting to the atmosphere is prohibited
  • Explain that new installations containing ODS are not permitted, and that replacement gases must be handled under the maker's procedures
  • Explain who makes the entries and who countersigns them, following the company procedure and any flag guidance

What the inspector looks for

  • A list of all equipment containing ODS that agrees with the IAPP Supplement
  • Entries for each full or partial recharge, repair or maintenance, deliberate or accidental release, landing to a reception facility and supply to the ship
  • Quantities recorded in kg with the gas type (for example R22) and the date
  • Refrigerant consumption that looks reasonable and leaks that were followed up
  • Any electronic record book approved by the flag

Have ready to show

  • ODS Record Book
  • IAPP Certificate and Supplement (the ODS equipment list)
  • Refrigerant stock and cylinder records, and landing receipts
  • PMS records of refrigeration and AC maintenance
  • The company SMS procedure

Avoid

  • Refrigerant bought or used with no matching entry
  • An equipment list that does not match the IAPP Supplement
  • Frequent top-ups with no recorded repair
  • Engineers unaware that the record book exists or what goes in it

Practise in the interview trainer All questions